1000 MW机组蛇形管式高压加热器泄漏原因分析  被引量:1

Cause Analysis on the Leakage of 1000 MW Snake-tube Type High Pressure Heater

在线阅读下载全文

作  者:刘响亮[1] 胡新元 任宁博 Liu Xiangliang;Hu Xinyuan;Ren Ningbo(Xi'an Thermal Power Research Institute Co Ltd,Xi'an 710032;Xi'an Yitong Thermal Technology Service Co Ltd,Xi'an 710032)

机构地区:[1]西安热工研究院有限公司,西安710032 [2]西安益通热工技术服务有限责任公司,西安710032

出  处:《中国特种设备安全》2022年第3期79-81,86,共4页China Special Equipment Safety

摘  要:国内某电厂采用了首台具有知识产权的1000 MW机组蛇形管式高压加热器,运行过程中出现泄漏.本文采用内窥镜检查发现泄漏是由集箱管接头处换热管断裂引起的,对换热管断口形貌、高压加热器运行数据以及生产制造记录方面进行研究分析.结果表明:在高压加热器生产制造过程中集箱管接头角焊缝处产生的缺陷和管接头处存在的绞刀痕是引起换热管泄漏断裂的主要原因.Leakage was found during the operation of a 1000 MW snake-tube type high pressure heater,which was the first application in a domestic power plant with independent intellectual property.The leakage was caused by the fracture of the heat exchange pipe at the header nozzle through endoscopy.By further analysis of the fracture morphology of the pipe,the operation data and manufacture records,it’s confirmed that the welding defects in the fillet and the cutter mark at the reducing diameter of header nozzle are the main reasons of leakage and fracture of the heat exchange tube.

关 键 词:蛇形管式高压加热器 集箱管接头 泄漏 绞刀痕 断口形貌 