作  者:孙昊飞 于静洁 毕艳孟[1,2] 孟凡盛 邱春生 王栋 王少坡[1,2] SUN Haofei;YU Jingjie;BI Yanmeng;MENG Fansheng;QIU Chunsheng;WANG Dong;WANG Shaopo(School of Environmental and Municipal Engineering,Tianjin Chengjian University,Tianjin 300384,China;Tianjin Key Laboratory of Aquatic Science and Technology,Tianjin 300384,China)

机构地区:[1]天津城建大学环境与市政工程学院,天津300384 [2]天津市水质科学与技术重点实验室,天津300384

出  处:《环境工程学报》2022年第2期421-429,共9页Chinese Journal of Environmental Engineering

基  金:天津市科技计划项目(20YDTPJC00470)。

摘  要:为探究连续流反应器在经历长期停运后的性能恢复情况,重启一个已停止运行150 d的厌氧氨氧化附着膜膨胀床(AAFEB)反应器,恢复了其脱氮性能,且考察了恢复策略的可行性、颗粒污泥性质的变化及其菌群结构的改变情况。结果表明:通过逐渐降低水力停留时间(HRT)(由13 h至3 h)和逐步提高进水总氮(TN)浓度(由(67.58±4.02)mg·L^(-1)至(374.93±10.76)mg·L^(-1))的方式,在72 d的恢复期中,氮去除率(NRR)由0.117kg·(m^(3)·d)^(-1)提升至2.553 kg·(m^(3)·d)^(-1),略高于反应器停运前((2.316±0.125)kg·(m^(3)·d)^(-1)),说明该AAFEB系统的脱氮性能恢复成功。在恢复期的第21天和第63天,反应器中部污泥的平均粒径分别为644.70μm和741.65μm,均超过停运前中部污泥的平均粒径(602.24μm)。g_Candidatus_Kuenenia为系统中厌氧氨氧化菌(AnAOB)的优势菌种,而g_Candidatus_Brocadia对长期停运后恢复期条件的适应能力较强。这说明AAFEB系统内AnAOB具有良好的韧性,恢复策略可行,在经历长期停运后,AAFEB系统的脱氮性能可以得到恢复。To explore the performance recovery of a continuous flow reactor after long-term shutdown,an anaerobic attached film expanded bed(AAFEB)reactor which had been shut down for 150 days was restarted to recover its nitrogen removal performance,and the feasibility of recovery strategy and the changes in granular sludge properties and the changes of microbial community structure were investigated.The results showed that by gradually reducing the hydraulic retention time(HRT)(from 13 h to 3 h)and gradually increasing the influent total nitrogen(TN)concentration(from(67.58±4.02)mg·L^(-1) to(374.93±10.76)mg·L^(-1)),the nitrogen removal rate(NRR)increased from 0.117 kg·(m^(3)·d)^(-1) to 2.553 kg·(m^(3)·d)^(-1),which was slightly higher than that before reactor shutdown((2.316±0.125)kg·(m^(3)·d)^(-1)),indicating that the nitrogen removal performance of AAFEB system recovered successfully.On the 21st day and the 63rd day of the recovery period,the average particle size of the sludge in the middle of the reactor were 644.70μm and 741.65μm,respectively,which were larger than that of the sludge before shutdown(602.24μm).g_Candidatus_Kuenenia is the dominant genus of anaerobic ammonium oxidation bacteria(AnAOB)in the system,while g_Candidatus_Brocadia adapted to the recovery conditions after long-term shutdown.This indicated that AnAOB in AAFEB system was resilient enough for the recovery with this strategy.After long-term shutdown,the nitrogen removal performance of AAFEB system can be recovered.

关 键 词:厌氧氨氧化附着膜膨胀床 恢复策略 颗粒污泥 菌群结构 

分 类 号:X703[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象