Preparation and Application of Polymerized High Internal Phase Emulsion Monoliths for the Preconcentration and Determination of Malachite Green and Leucomalachite Green in Water Samples  

在线阅读下载全文

作  者:Li-Ping Jiang Na Li Lin-Qi Liu Xian Zheng Fu-You Du Gui-Hua Ruan 

机构地区:[1]Guangxi Key Laboratory of Electrochemical and Magnetochemical Functional Materials,College of Chemistry and Bioengineering,Guilin University of Technology,Guilin 541004,China [2]College of Biological and Environmental Engineering,Changsha University,Changsha 410022,China

出  处:《Journal of Analysis and Testing》2020年第4期264-272,共9页分析检测(英文)

基  金:supported by the National Natural Science Foundation of China(Grant No.21964006,and 21665006);the Natural Science Foundation from Hunan Province(No.2020JJ4640 and 2017JJ3342);the Natural Science Foundation from Guangxi Zhuang Autonomous Region(No.2018GXNSFAA138134);the Scientific Research Found of Changsha University(SF1934),respectively.

摘  要:Polymerized high internal phase emulsion(polyHIPE)monoliths were prepared and applied as adsorbent materials for solid-phase extraction(SPE)of malachite green(MG)and leucomalachite green(LMG)from water samples.The polyHIPE monoliths were prepared by post-functionalization of monolithic surface with 6-aminocaproic acid(ACA)via ring opening reaction of epoxy groups in glycidyl methacrylate(GMA)-based polyHIPEs,and then applied to the preconcentration and determination of trace MG and LMG in environmental water samples by combing with high-performance liquid chromatog-raphy(HPLC).Taking MG and LMG as targets,main factors affecting SPE performance of the polyHIPE monoliths were investigated.Under the optimized conditions,the ACA-functionalized polyHIPE monoliths could effectively preconcentrate MG and LMG from 150 mL of water samples,and the recoveries of MG and LMG at three spiked levels were ranged from 84.8 to 97.4%with the relative standard deviations(RSDs)lower than 6%.The proposed method exhibited good linearity in the range of 2-200 ng mL^(-1),with low limits of detection of 17.0 and 8.7 pg mL^(-1)for MG and LMG,respectively.In addi-tion,the prepared ACA-modified polyHIPE monolith showed good durability and stability,and it could be reused for 200 cycles without obvious losing the extraction performance.

关 键 词:High internal phase emulsion Solid-phase extraction High-performance liquid chromatography Malachite green Leucomalachite green 

分 类 号:O658.2[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象