Dedicated SiPM array for GRD of GECAM  

在线阅读下载全文

作  者:D.L.Zhang X.L.Sun Z.H.An X.Q.Li X.Y.Wen K.Gong C.Cai Z.Chang G.Chen C.Chen Y.Y.Du M.Gao R.Gao D.Y.Guo J.J.He D.J.Hou Y.G.Li C.Y.Li G.Li L.Li X.F.Li M.S.Li X.H.Liang X.J.Liu Y.Q.Liu F.J.Lu H.Lu B.Meng W.X.Peng F.Shi H.Wang J.Z.Wang Y.S.Wang H.Z.Wang X.Wen S.Xiao S.L.Xiong Y.B.Xu Y.P.Xu S.Yang1 X.Zhou J.W.Yang Fan Zhang S.N.Zhang C.Y.Zhang C.M.Zhang Fei Zhang X.Y.Zhao 

机构地区:[1]Institute of High Energy Physics,CAS,Beijing 100049,China [2]State Key Laboratory of Particle Detection and Electronics,Beijing 100049,China

出  处:《Radiation Detection Technology and Methods》2022年第1期63-69,共7页辐射探测技术与方法(英文)

基  金:This research was supported by the Key Research Program of Frontier Sciences,Chinese Academy of Sciences(QYZDBSSW-SLH012);the National Natural Science Foundation of China(11775251,11775252);the strategic leading science and technology program of Chinese Academy of Sciences(XDA 15360100,XDA 15360102).

摘  要:Purpose The discovery of gravitational waves and gamma-ray bursts heralds the era of multi-messenger astronomy.With the adoption of two small satellites to achieve the all-sky monitoring of gamma-ray bursts,the gravitational wave highenergy electromagnetic counterpart all-sky monitor(GECAM)possesses a quasi-real-time early warning ability and plays an important role in positioning the sources of gravitational waves and in subsequent observations.Each satellite of GECAM was fitted with 253-inch-diameter gamma-ray detectors(GRD),covering an energy range of 8–2 MeV.GRDs have adopted silicon photomultiplier tubes(SiPM)in lieu of photomultiplier tubes(PMT)to adapt to the dimensional limitations of micro-satellites.Methods A unique 3-inch circular SiPM array was designed.In this design,646×6 mm chips were arranged evenly in a circular manner with the seams filled with reflecting films,thus achieving satisfactory uniformity of light collection.The integrated pre-amplifier circuit on the back of the SiPM array adopted two-level grouping and summing;further,it achieved a satisfactory signal-to-noise ratio.Two high-gain and low-gain channels were adopted to achieve a large dynamic range,and two independent power supply units were used,where each unit can be closed separately,thus improving reliability.Results Performance studies show that this SiPM array meets the requirements of GECAM.Conclusion A 3-inch SiPM array have been developed that uses grouped summation,reflective films,a circular arrangement,two groups of independent power supplies,high-and low-gain signals,differential signal output technologies,etc.This solution can be used not only for GECAM,but also as a general solution for SiPM-based scintillation detectors.

关 键 词:SIPM GECAM GAMMA-RAY Signal-to-noise ratio Reflecting film Pre-amplifier 

分 类 号:V423[航空宇航科学与技术—飞行器设计]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象