检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:马永杰 王星怡 韩聪颖 蔺玉红 马慧 张雪艳[1] MA Yongjie;WANG Xingyi;HAN Congying;LIN Yuhong;MA Hui;ZHANG Xueyan(School of Agriculture,Ningxia University,Yinchuan 750021,China)
机构地区:[1]宁夏大学农学院,银川750021
出 处:《新疆农业科学》2022年第4期1016-1024,共9页Xinjiang Agricultural Sciences
基 金:自治区重大研发计划(2018BBF33004);园艺学产教融合示范专业建设项目(030103040021);自治区科技创新领军人才(KJT2017001);自治区青年拔尖人才(2017)。
摘 要:【目的】研究日光温室后墙自走式雾化降温机在夏季高温情况下,不同运行模式上、中、下午温室内水平和垂直方向温湿度变化规律,为夏季雾化降温机高效运行提供理论支撑。【方法】利用自主研发的设施悬挂自走式雾化降温、喷药、喷肥一体装置,设计雾化降温机运行时间分别为4、8、12 min,间隔时间分别为20、40、60 min,总计9种运行模式,在夏季晴天高温条件下开展降温效果评价试验。【结果】最佳运行模式分别为上午运行12 min,间隔60 min;中午运行8 min,间隔20 min;下午运行12 min,间隔20 min。水平方向3 m处雾化降温效果最好,平均降温1.3℃,增湿7.6%;垂直方向2.5 m处的降温效果最好,可降温2.3℃,增湿11%。【结论】日光温室后墙自走式雾化降温机上午、中午、下午分别进行12-60、8-20、12-20运行模式,能够为日光温室越夏生产起到良好的降温效果。【Objective】To study the variation law of temperature and humidity in horizontal and vertical direction of solar greenhouses in different operation modes under the condition of high temperature in summer.This result provides theoretical support for the efficient operation of the summer atomization cooling machine,which can help to solve the problem of high temperature and low humidity in the summer production of solar greenhouses.【Method】The self-propelled atomization machine integrated cooling,spraying pesticides and fertilizer was used,the running time was 4,8,12 minutes,and the interval time was 20,40 and 60 minutes,respectively.A total of 9 operation modes were used to evaluate the cooling effect under the condition of high temperature on sunny days in summer.【Result】The best operating modes was running 12 minuteswith an interval of 60 minutes in the morning,running 8 minutes with an interval of 20 minutes at noontime,and running 12 minutes with an interval of 20 minutes in the afternoon.The best atomization cooling effect was found at 3 meters in the horizontal direction,the air temperature reduced on average of 1.3℃,and air humidity increased on a average of 7.6%.Meanwhile,the best cooling effect was detected at 2.5 meters in the vertical direction and the air temperature reduced on average of 2.3℃,and air humidity increased on a average of 11%.【Conclusion】T Compared with the control greenhouse,the self-propelled atomization cooling machine on the back wall of the solar greenhouse operates in 12-60,8-20,and 12-20 operating modes in the morning,noon,and afternoon respectively,which can have a cooling effect in the summer production of the solar greenhouse.
分 类 号:S22[农业科学—农业机械化工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49