检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:徐爽[1] 徐聪聪 郭腾达 林培军[1] 李凤春[1] 王继林[1] 顾清宇 栾日坚 张玉强[1] 李增胜 杨慧[1] 魏玮[1] XU Shuang;XU Congcong;GUO Tengda;LIN Peijun;LI Fengchun;WANG Jjilin;GU Qingyu;LUAN Rijian;ZHANG Yuqiang;LI Zengsheng;YANG Hui;WEI Wei(Testing Center of Shandong Bureau of China Metallurgical Geology Administration,Jinan 250014,China;The 801 Institute of Hydrogeology and Engineering Geology,Shandong Provincial Bureau of Geology&Mineral Resources,Jinan 250014,China;Shandong Institute of Geological Sciences,Jinan 250014,China)
机构地区:[1]中国冶金地质总局山东局测试中心,山东济南250014 [2]山东省地质矿产勘查开发局八〇一水文地质工程地质大队,山东济南250014 [3]山东省地质科学研究院,山东济南250014
出 处:《岩矿测试》2022年第2期251-259,共9页Rock and Mineral Analysis
基 金:山东省自然科学基金项目(ZR2019BD017)。
摘 要:近年来对稀有多金属矿的研究越来越趋向于微区化、微量化,作为其重要研究手段之一,电子探针定量分析在微量元素测试方面取得很大的进展。在微量测试过程中,除了增大测试束流,提高测试时间来降低检出限以外,更要注意去除来自其他元素,特别是主量元素的干扰。在日常测试稀有多金属样品的过程中,Si、Ta、W三个元素存在相互干扰,这种干扰对影响微量元素的测试结果,且因含量低不易被察觉,从而影响最终结论的准确性。本文以SPI标样公司的SiO;、金属Ta和W为研究对象,查明Si、Ta、W三者之间在不同测试条件下的干扰关系并给出建议:硅酸盐测试中,Si建议使用TAP-Kα,Ta和W建议使用LIF-Lα;铌钽矿测试中,Si、Ta、W建议分别使用PET-Kα、PET-Mα和TAP-Mβ,并配合Ta对Si的干扰校正测试结果更为准确。BACKGROUND: In recent years, the study of rare polymetallic ore tends to be increasingly detailed. As one of the important research methods, electron probe quantitative analysis has made great progress in trace element measurement. During analysis, in addition to increasing the beam size and time to reduce the detection limit, more attention should be paid to removing the interference from other elements, especially the main elements. During the routine testing of rare polymetallic samples, Si, Ta, W interfere with each other. Such interference affects the analytical results of trace elements, and is not easily detected due to its low content, thus affecting the accuracy of the final conclusion.OBJECTIVES: To determine the interference relationship among Si, Ta and W under different analytical conditions.METHODS: Taking SiO;, metal Ta and W of SPI as the research object, each element was analyzed under different conditions by electron probe microanalyzer.RESULTS: In the analysis of silicate, TAP-Kα is used for Si, and LIF-Lα is recommended for Ta and W. In the analysis of niobium tantalum ore, it is suggested to use PET-Kα, PET-Mα and TAP-Mβ for Si, Ta and W, respectively;since 100% Ta will produce about 0.1% Si, therefore, the results are more accurate with the interference correction of Ta on Si.CONCLUSIONS: It is important to understand the spectral peak stripping method and the principle of element interference and spectral peak overlap, adjusting the parameters according to the actual situation to ensure the accuracy of data.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28