作  者:栗文明 徐纬 陈佳佳 黄思琦 李军 LI Wenming;XU Wei;CHEN Jiajia;HUANG Siqi;LI Jun(Jiangsu Provincial Environmental Engineering Technology Co.,Ltd;Engineering Research Center of Standardized Construction and Intelligent Management of Industrial Parks;Jiangsu Province Engineering Research Center of Standardized Construction and Intelligent Management of Industrial Parks:Nanjing 210036,China)

机构地区:[1]江苏省环境工程技术有限公司 [2]江苏省工业园区规范化建设及智慧化管控工程研究中心 [3]江苏省重点行业减污降碳协同控制工程研究中心,江苏南京210036

出  处:《水处理技术》2022年第5期154-156,共3页Technology of Water Treatment

基  金:江苏省环保集团科技项目计划(JSEP-TZ-2021-1001-RE)。

摘  要:江苏某钢铁企业废水深度处理设计进水规模为1.5×10^(4) m^(3)/d,采用“超滤+反渗透+钠床”组合工艺,反渗透浓水再经浓水反渗透后进一步回收产水。超滤设计膜通量为50 L/(m^(2)·h),回收率≥90%,反渗透设计通量19 L/(m^(2)·h),回收率≥75%,浓水反渗透设计通量16 L/(m^(2)·h),回收率≥75%。出水经多级回用分质供水,系统产水的浓盐水送至高炉冲渣,实现了全厂无废水外排。膜系统设备投资1600万元,成本为1.23元/m^(3)进水。The design influent scale is 15000 m^(3)/d in the advanced wastewater treatment of a steel enterprise in Jiangsu Province.The combined process of"ultrafiltration+reverse osmosis+sodium bed"was adopted and the concentrated water of reverse osmosis was recovered by the concentrated reverse osmosis.The UF permeate flux was 50 L/(m^(2)·h)and the recovery rate was≥90%.The RO permeate flux was 19 L/(m^(2)·h)and the recovery rate was≥75%.The concentrated RO permeate flux was 16 L/(m^(2)·h)and the recovery rate was≥75%.The effluent was supplied by multistage reuse and grading,and the concentrated brine produced by the system was sent to the blast furnace for slagging so that no wastewater was discharged from the plant.The investment in the membrane system equipment was 16 million RMB and the cost of water treatment was 1.23 RMB/m^(3) based on the influent.

关 键 词:超滤 反渗透 双膜法 近零排放 浓盐水 

分 类 号:TQ028.8[化学工程] X757[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象