检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Diane N.Sayah Wenzhen Zuo Javier Mazzaferri Luke Beaton Santiago Costantino Mark R.Lesk
机构地区:[1]Centre de recherche de l'Hôpital Maisonneuve-Rosemont,Montreal,QC,Canada [2]Département d'Ophtalmologie,Universitéde Montréal,Montreal,QC,Canada [3]Facultéde Médecine,Universitéde Montréal,Montreal,QC,Canada
出 处:《Annals of Eye Science》2018年第1期497-497,共1页眼科学年鉴(英文)
摘 要:Background:Over the years,a variety of non-invasive techniques have been developed to allow the measurement of blood flow in living human eyes.However,none of the existing techniques has yet been adopted in clinical practice due to their limitations and lack of standardization.Moreover,no reliable technique is currently available to measure the pulsatile choroidal blood flow(PCBF).We propose a novel method based on video-rate optical coherence tomography(OCT)imaging and automated segmentation to measure the pulsatile component of choroidal blood flow in vivo,and demonstrate its repeatability.Methods:Adapted from our earlier work(Beaton et al.),this method uses video-rate OCT with enhanced depth imaging and automated segmentation of the choroid to measure the pulsatile choroidal volume change.Imaging is carried out at the fundus for less than a minute at 7 Hz.In each frame,choroidal thickness(CT)is measured by a segmentation algorithm based on graph cuts using an edge-probability weighting scheme.The algorithm computes the CT change corresponding to choroidal filling over the time-series and subsequently derives the pulsatile choroidal volume change through an approximate model of the eye.Fifty-eight subjects were recruited from the Maisonneuve-Rosemont Hospital and PCBF was measured twice in one eye within the same session and by a single examiner.Repeatability was assessed using the Bland-Altman plot and Intraclass correlation coefficient as calculated with SPSS.Results:Two measurements of PCBF were successfully obtained for each eye using our technique.The average measures ICC for choroidal volume change was 0.929(95%CI,0.881,0.958),showing good to excellent repeatability.The Bland-Altman plot and Pearson coefficient(r=0.840,P<0.001)showed agreement and a strong correlation respectively between intra-session measurement of OR in all examined eyes.Conclusions:This study confirms the high repeatability of pulsatile choroidal blood flow measurements obtained with our optical method,allowing further investigation o
关 键 词:Pulsatile choroidal blood flow(PCBF) optical coherence tomography(OCT) novel technique REPEATABILITY
分 类 号:TP3[自动化与计算机技术—计算机科学与技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.219.83.70