检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:孙清石 SUN Qing-shi(Tianjin TBEA Electric Transformer Co.,Ltd.,Tanjin 300308,China)
机构地区:[1]天津市特变电工变压器有限公司,天津300308
出 处:《变压器》2022年第4期11-14,共4页Transformer
摘 要:对于电抗器具有电流大、匝数少的特点,其绕组一般采用多根导线并联的分段层式绕制方法,而分段层式的换位方法一般采用每段每层分别完全换位,这种换位方法虽然可以达到完全换位的目的,但是大大降低了绕组绕制的效率。本文中作者针对该问题采用漏磁对导线产生的涡流进行了精确计算,优化了换位方法,以实际的电抗器作为计算实例,进行了详细的说明。The reactor has the characteristics of large current and few turns.Its coil generally adopts the subsection layer winding method with multiple wires in parallel,while the subsection layer transposition method generally adopts the complete transposition of each section and each layer.Although this transposition method can achieve the purpose of complete transposition,it greatly reduces the efficiency of coil winding;Aiming at this problem,this paper uses magnetic flux leakage to accurately calculate the eddy current generated by the conductor,optimizes the transposition method,and takes the actual reactor as an example.