检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Sixi YANG Kexin ZHANG Jinxia LIU
机构地区:[1]Experimental Center of Pathogenic Biology, Chengde Medical University, Chengde 067000, China
出 处:《Medicinal Plant》2022年第2期18-20,36,共4页药用植物:英文版
摘 要:[Objectives]Loop-mediated isothermal amplification(LAMP)was developed and optimized for rapid and specific diagnosis of Brucella infection.[Methods]The conserved sequence of the brucellosis standard strain Omp25 gene fragment was selected,primers needed in the loop-mediated isothermal amplification system were designed,and nucleic acid of the standard strain was extracted.Primers,reaction system,reaction conditions and stain types were repeatedly optimized to establish an improved LAMP detection kit for brucellosis.Confirmatory tests were performed on blood samples from clinically confirmed cases and their sensitivity and specificity were confirmed.Then,the detection technology and kit were applied to the detection and screening of suspected B.melitensis in pastoral areas.Finally,SPSS21.0 was used to evaluate the consistency of LAMP and Q-PCR.[Results]LAMP system was optimized,and the optimal final concentrations of MgSO_(4) and betaine were 8 and 0.8 mmol/L,respectively.The sensitivity and specificity of the modified LAMP technique were verified by using human blood samples with confirmed brucellosis.In LAMP specific test,there was no nonspecific amplification,indicating good specificity.In the LAMP sensitivity test,the minimum detection line for B.melitensis,B.abortus,and B.suis was 10 copies/μL,which was an order of magnitude higher than that for Q-PCR.The consistency between modified LAMP and Q-PCR was 0.941.The established Brucella LAMP kit was used to detect the blood samples of 200 sheep suspected to be infected with Brucella.The LAMP kit detected 42 positive samples,with a positive rate of 21%and a detection sensitivity of 100%.Negative specimens were detected in 158 cases,with a specificity of 100%.There were 41 negative samples detected by PCR,with a positive rate of 20.5%.The detection specificity was consistent with that of LAMP kit.[Conclusions]The modified LAMP for Brucella has been successfully established.This technology is characterized by good sensitivity and specificity,low cost and high effic
关 键 词:BRUCELLA Loop-mediated isothermal amplification Omp25 Diagnostic kit DEVELOPMENT
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222