The Efficacy of In-Phase and Quadrature Demodulation in Electronic Fetal Heart Rate Monitoring During Labor  被引量:1

在线阅读下载全文

作  者:Yiheng Liang Ping Liu Shaomei Yan Yun Li Duijin Chen Shangrong Fan 

机构地区:[1]Department of Obstetrics and Gynecology,Peking University Shenzhen Hospital,Shenzhen,Guangdong 518036,China [2]Shenzhen Key Laboratory on Technology for Early Diagnosis of Major Gynecological Diseases,Shenzhen,Guangdong 518036,China [3]Department of Obstetrics and Gynecology,The Third Affiliated Hospital of Guangzhou Medical University,Guangzhou,Guangdong 510150,China.

出  处:《Maternal-Fetal Medicine》2022年第2期113-120,共8页母胎医学杂志(英文)

基  金:Shenzhen Science and Technology Innovation Commission(JCYJ20180228162311024)。

摘  要:Objective:To investigate the efficacy of in-phase and quadrature(IQ)demodulation in electronic fetal heart rate monitoring(EFM)to reduce false reports of fetal heart rate(FHR)doubling or halving.Methods:This is a prospective cohort study.A total of 263 full-term pregnant women who delivered at Peking University Shenzhen Hospital between August 2019 and July 2020 were prospectively enrolled in the study.FHR monitoring began when the cervix was dilated to 2-3 cm and continued until delivery.Raw fetal Doppler audio signals and internal and external cardiotocography curves from internal electrode monitoring,EFM with conventional demodulation(external),and EFM with IQ demodulation(external)were acquired to compare FHR doubling and halving time.In cohort 1,FHR was compared between IQ demodulation and conventional demodulation.In cohort 2,FHR was compared between IQ demodulation,conventional demodulation,and internal FHR monitoring.Count data were statistically analyzed using the Chi-squared test,and measurement data were statistically analyzed usingt-test for correlation coefficients,and Bland-Altman analysis for concordance ranges.Results:To compare IQ demodulation and conventional demodulation,225 pregnant women were monitored for a total of 835,870 seconds.The beat-to-beat interval of FHRs in raw fetal Doppler audio signals was used as the reference.The results showed a doubling time of 3401 seconds(0.407%,3401/835,870)and a halving time of 2918 seconds(0.349%,2918/835,870)with conventional demodulation,compared to 241 seconds(0.029%,241/835,870)and 589 seconds(0.070%,589/835,870),respectively,with IQ demodulation.IQ demodulation reduced FHR doubling by approximately 93%(3160/3401)and FHR halving by approximately 80%(2329/2918)compared to conventional demodulation(P<0.01).Conclusion:EFM with IQ demodulation significantly reduces false FHR doubling and halving,with an efficacy similar to that of internal FHR monitoring.

关 键 词:Fetal monitoring Heart rate fetal Doubling Halving IQ demodulation 

分 类 号:R714.5[医药卫生—妇产科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象