作 者:崔云峰[1] 卫铁军[1] 盛强 郭靖涛[3] 于宏彬 王文静 赵丽莉[1] 王文月 龙晓东 陈建建 赵国栋 巩悦勤 CUI Yunfeng;WEI Tiejun;SHENG Qiang;GUO Jingtao;YU Hongbin;WANG Wenjing;ZHAO Lili;WANG Wenyue;LONG Xiaodong;CHEN Jianjian;ZHAO Guodong;GONG Yueqin(Catheterization Room,Chengde Central Hospital,Chengde,Hebei Province 067000,China;Department of Interventional Vascular Surgery,Chengde Central Hospital,Chengde,Hebei Province 067000,China;Department of Cardiology,Chengde Central Hospital,Chengde,Hebei Province 067000,China;GE Healthcare(China)ICS Modality,Beijing 100176,China)
机构地区:[1]承德市中心医院导管室,河北承德067000 [2]承德市中心医院介入血管外科,河北承德067000 [3]承德市中心医院心内科,河北承德067000 [4]通用电气(中国)医疗系统血管机产品部,北京100176
出 处:《实用放射学杂志》2022年第4期639-642,共4页Journal of Practical Radiology
基 金:承德市科技计划项目(202102A016).
摘 要:目的探讨支架血流精显(StentVesselViz)技术在冠状动脉支架植入术中的应用价值.方法回顾性收集接受冠状动脉支架植入并经StentVesselViz技术指导球囊后扩张的27例患者资料,根据冠状动脉造影定量分析(QCA)测量支架直径,根据StentVesselViz图像进行支架可视化分析.结果27例患者共30处病变,共植入37枚支架;共实施StentVesselViz72次,单次技术成功率为90.9%,未见严重治疗相关不良事件.平均实施时间为(12.10±1.22)s,单次实施的放射剂量为(13.7±4.01)mGy,手术放射剂量为(1494.83±24.02)mGy;扩张前后支架偏心指数有统计学差异(P=0.00);支架可视化分析为优良占93.9%.结论StentVesselViz技术可提高经皮冠状动脉介入(PCI)术中支架可视性并可指导球囊后扩张,临床应用简便安全.Objective To investigate the application value of StentVesselViz in coronary stent implantation.Methods The data of 27 patients who underwent coronary stent implantation and post-dilatation with the guidance of StentVesselViz were retrospectively collected.Stent diameter was measured using quantitative coronary angiography(QCA)images.The stent visualization analysis was performed according to StentVesselViz images.Results 27 patients with 30 lesions received 37 stents deployment.StentVesselViz was performed 72 times.The single technical success rate was 90.9%.No serious treatment-related adverse events were observed.The average implementation time was(12.10±1.22)s.The single implement dose was(13.7±4.01)mGy.The total operation dose was(1494.83±24.02)mGy.A significant difference in stent eccentricity index before and after post-dilation was observed(P=0.00).The evaluation of stent visualization showed that fine or above quality accounted for 93.9%.Conclusion StentVesselViz technology can improve the visibility of the stent and guide post-balloon dilatation during percutaneous coronary intervention(PCI).Its clinical application is simple and safe.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117