改良ICEAS+MBBR工艺在高标准污水厂提标改造中的应用  

Application of Modified ICEAS+MBBR Process in Upgrading and Reconstruction of High Standard WWTP

在线阅读下载全文

作  者:封汇川 陈良 周波[1,2,3] 倪方坤 FENG Huichuan;CHEN Liang;ZHOU Bo;NI Fangkun(East China Branch,China Machinery International Engineering Design&Research Institute Co.,Ltd.,Nanjing210000,China;Hunan Engineering Research Center for Water Treatment Process&Equipment,Changsha410007,China;Changsha Innovation Center for Water Treatment Process&Equipment,Changsha410007,China;Yunnan Xinlian Environmental Technology Co.,Ltd.,Kunming650000,China)

机构地区:[1]中机国际工程设计研究院有限责任公司华东分院,江苏南京210000 [2]湖南省水处理过程与装备工程技术研究中心,湖南长沙410007 [3]长沙市水处理过程与装备技术创新中心,湖南长沙410007 [4]云南新联环境科技有限公司,云南昆明650000

出  处:《净水技术》2022年第5期144-149,共6页Water Purification Technology

基  金:湖南省高新技术产业科技创新引领计划(2020SK2042,2022GK4062);湖南省重点研发计划(2022SK2067)。

摘  要:云南某污水处理厂处理规模为3.0万m^(3)/d,需在新增较少用地情况下进行提标改造,实现出水水质和处理水量双提升。针对现有主体间歇式循环延时曝气活性污泥法(ICEAS)工艺处理效果有限的情况,通过多方案比选,将其改造为“改良ICEAS+MBBR”工艺,挖潜其处理能力并强化生化段对COD_(Cr)、氨氮、TN和TP等污染物的去除。通过中试试验和工程实例表明,改造后的工艺处理日均水量可提高17%,部分出水水质可由一级A标准提高至Ⅳ类标准,本工程仅新增占地面积为84m^(2)的碳源加药间,即可实现高标准污水厂提标改造。本工程新增运营成本为0.22元/m^(3),改造后单位经营成本为1.05元/m^(3)。本项目旨在为同类污水处理工程提供参考。The total treatment scale of a wastewater treatment plant(WWTP) in Yunnan Province is 3.0×10^(4) m^(3)/d,which needs to take upgrading and reconstruction with adding less new land,so as to realize the dual-upgrading of effluent quality and treatment capacity.In view of the limited treatment effect of the existing ICEAS process,multi schemes are compared and selected." Modified ICEAS+MBBR" process is chosen to strengthen the removal effect of COD_(Cr),ammonia nitrogen,TN and TP in the biochemical section and improved treatment capacity.The pilot-scale test and engineering example show that the treated water volume can be increased by 17%,and part of the effluent water quality can be improved from first class A criteria to class Ⅳ criteria after upgrading and reconstruction.Only an area of 84 m^(2) of new added carbon source dosing room is required to complete the upgrading and reconstruction of high standard WWTP.The newly increased operating cost is 0.22 yuan/m^(3),and the unit operating cost after transformation is 1.05yuan/m^(3).The results of this study could be references for engineering practice and treatment of similar wastewaters.

关 键 词:改良ICEAS 移动床生物膜反应器(MBBR) 高标准 双提升 污水处理厂 

分 类 号:TU992[建筑科学—市政工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象