奶油制备CT造影剂观察消化道出血的实验研究  被引量:1

An experimental study on observing digestive tract bleeding with CT contrast agent prepared by cream

在线阅读下载全文

作  者:沈萍[1] 元建鹏[1] 黄文生[1] 席维佳 张伟[1] 赖伟建 SHEN Ping;YUAN Jianpeng;HUANG Wensheng;XI Weijia;ZHANG Wei;LAI Weijian(Department of Radiology, The Seventh Affiliated Hospital of Sun Yat-sen University, Shenzhen 518107, China)

机构地区:[1]中山大学附属第七医院放射科,广东深圳518107

出  处:《暨南大学学报(自然科学与医学版)》2022年第3期269-275,共7页Journal of Jinan University(Natural Science & Medicine Edition)

基  金:广东省科技计划资助项目(2014A020212126);深圳市光明区卫生计生局中医药科研基金项目(GM2019020027)。

摘  要:目的:以奶油为主要原料制备一种胃肠道CT低密度造影剂,并研究其对消化道出血的诊断价值。方法:以可食用淡奶油为原料,添加少量瓜尔豆胶,经搅拌机搅打后制得低密度造影剂。在CT扫描图像上观察其均匀性并测量CT值、比较其与血凝块的密度差异;在离体猪小肠中以混入肝素的血浆0.1、0.2、0.4mL模拟微量的消化道出血,观察该低密度造影剂对出血灶的显示效果,并比较其与中性对比剂(水)对出血的显示效果。结果:制得的低密度造影剂的CT扫描图像较均匀,CT值范围为-500~-700 Hu,与血凝块的密度差异明显;其能准确地显示和区分0.1、0.2、0.4 mL的出血灶,相对于中性对比剂(水)对出血的显示具有明显的优势。结论:以奶油添加瓜尔豆胶制备的胃肠道CT低密度造影剂均匀性良好,可以准确地显示出血灶,相对于中性对比剂(水)对消化道出血的诊断更为优越,值得进一步在临床诊断中试用。Objective:A low-density CT contrast agent for the gastrointestinal tract was prepared with cream as the primary raw material,and its diagnostic value for gastrointestinal bleeding was explored.Methods:The low-density contrast agent was prepared with edible whipped cream as raw material and mixed with a small amount of guar gum.After that,the homogeneity of the contrast agent was observed on the CT scan image,the CT value was measured,and its density difference between the blood clot was compared.In the isolated pig small intestine,0.1,0.2,and 0.4 mL of plasma mixed with heparin was used to simulate a small trace amount of gastrointestinal bleeding to observe the display effect of the low-density contrast agent on the bleeding focus and was compared with the neutral contrast agent(water).Results:The CT scan image of the prepared low-density contrast agent is relatively uniform,with a CT value ranging from-500 to-700 Hu,which was significantly different from the density of blood clots.The low-density contrast agent accurately displayed and distinguished 0.1,0.2,and 0.4 mL bleeding focus.Compared with the neutral contrast medium(water),it showed apparent advantages in the display of bleeding.Conclusion:The gastrointestinal CT low-density contrast agent prepared with cream and guar gum had good uniformity and can accurately display the bleeding focus.It is superior to the neutral contrast agent(water)for diagnosing gastrointestinal bleeding and is worth further clinical trials.

关 键 词:消化道出血 CT 造影剂 

分 类 号:R81[医药卫生—放射医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象