某船主减速齿轮箱电动备用滑油泵启停故障处理  被引量:1

Start-stop failure treatment of electric standby lube oil pump in a ship’s main reduction gear box

在线阅读下载全文

作  者:刘五合 王鹏 韩浩然 曲俊国 LIU Wuhe;WANG Peng;HAN Haoran;QU Junguo

机构地区:[1]海装沈阳局,黑龙江哈尔滨150000 [2]北部战区海军保障部直属保障队,山东青岛266000 [3]中国船舶第七〇三研究所,黑龙江哈尔滨150078

出  处:《中国修船》2022年第3期17-19,共3页China Shiprepair

摘  要:文章以某船主减速齿轮装置电动备用滑油泵启停故障为研究对象,从电控系统分析,认为是滑油泵启动控制箱主接触器无法吸合的主要原因。根据故障原因,制定了更换新接触器的维修方案,确保了该船的电动备用滑油泵正常启停的工作状态。This paper takes the start-stop failure of an electric standby lube oil pump in a ship’s main reduction gear unit as the research object.Through the analysis of the electric control system,the failure is mainly attributed to the problem that the main contactor of the start control box in the lube oil pump cannot be actuated.Given this failure cause,a maintenance plan of replacing the contactor with a new one is developed to ensure that the ship’s electric standby lube oil pump starts and stops normally.

关 键 词:电动备用滑油泵 主接触器 吸合 

分 类 号:U672[交通运输工程—船舶及航道工程]

 