检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:苏昕 宁彬 杨文武 陈帅 葛慧娟 任磊 陶长桂[1] SU Xin;NING Bin;YANG Wen-wu;CHEN Shuai;GE Hui-juan;REN Lei;TAO Chang-gui(Department of Cardiology,Fuyang People’s Hospital Affiliated to Anhui Medical University,Fuyang 236000,Anhui,China)
机构地区:[1]安徽医科大学附属阜阳市人民医院心血管内科,安徽阜阳236000
出 处:《心脏杂志》2022年第2期174-177,共4页Chinese Heart Journal
基 金:安徽省卫生健康委科研项目(AHWJ2021b070);安徽医科大学校基金资助项目(2021xkj087)。
摘 要:目的探讨消融导管压力变异性与心房颤动(房颤)首次射频消融复发的相关性。方法连续选取2019年8月~2020年8月阜阳市人民医院收治的首次行射频消融术的房颤患者69例,所有患者均在CARTO3系统下行房颤射频消融术并恢复窦性心律,术中对消融压力-时间曲线进行数据采集分析。术后定期随访,观察患者是否复发,根据术后随访的结果,将患者分为复发组与未复发组,对压力数据进行两组比较,探讨消融导管压力变异性与房颤首次射频消融复发的相关性。结果所有患者术后平均随访14个月,房颤复发18例,未复发51例。复发组与非复发组有统计学意义的变量为左房前后径:[(45±7)vs.(39±7)]mm,P<0.05,首次发现房颤至手术时间[24(8,60)月vs.7(1,24)月,P<0.01],消融导管压力变异性(5.64±0.59)vs.(5.06±0.46),P<0.01,二元Logistic多因素回归分析显示消融导管压力变异性和左房前后径可做为房颤患者首次射频消融复发的独立预测因素,OR值、95%置信区间、P值分别为(9.489,2.080~43.280,P<0.01)和(1.152,1.019~1.302,P<0.05)。结论压力变异性及左房前后径可做为心房颤动患者首次行射频消融后房颤复发的预测因素。AIM To explore the correlation between the variability of catheter contact force measurements and the recurrence of the first radiofrequency ablation of atrial fibrillation.METHODS Sixty-nine patients with atrial fibrillation who underwent radiofrequency catheter ablation in Fuyang People’s Hospital from August 2019 to August 2020 were chosen for this study.All patients recovered sinus rhythm under the guidance of CARTO3 system for the first radiofrequency ablation and the force data were collected from the real-time contact force measurements.Patients were followed up regularly to observe the recurrence of atrial fibrillation after the ablation and they were divided into recurrence group and non-recurrence group.The correlation between the variability of catheter contact force measurements and the recurrence of the first radiofrequency ablation of atrial fibrillation was explored.RESULTS In this study,all patients were followed up for an average of 14 months after ablation and 18 patients had recurrence of atrial fibrillation while 51 patients had no recurrence.The anterior and posterior diameter of the left atrial in the recurrent group and non-recurrent group was:[(45±7)vs.(39±7)]mm,P<0.05.The time from the first discovery of atrial fibrillation to ablation was[24(8,60)months vs.7(1,24)months,P<0.01].Variability of ablation catheter contact force was(5.64±0.59)vs.(5.06±0.46),P<0.01,Binary logistic multivariate regression analysis showed that the anterior and posterior diameter of the left atrial and the variability of ablation catheter contact force were independent predictors of the recurrence of the first of ablation in patients with atrial fibrillation.OR values,95%confidence intervals and P values were 9.489,2.080-43.280,P<0.01 and 1.152,1.019-1.302,P<0.05.CONCLUSION Variability of ablation catheter contact force and left atrial anterior posterior diameter can be used as predictors of atrial fibrillation recurrence after the first radiofrequency ablation.
分 类 号:R541.75[医药卫生—心血管疾病]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.19.234.118