探讨垃圾焚烧电站旁路减温减压装置分析及计算  

Discuss on analysis and calculation of the bypass temperature reduction device of the waste incineration power station

在线阅读下载全文

作  者:韩俊 杨海艳 HAN Jun;YANG Haiyan(Wuxi Yadi Fluid Control Technology Co.,Ltd.,Wuxi,Jiangsu 214161,China)

机构地区:[1]无锡市亚迪流体控制技术有限公司,江苏无锡214161

出  处:《农业工程与装备》2022年第2期19-21,25,共4页AGRICULTURAL ENGINEERING AND EQUIPMENT

摘  要:旁路系统是垃圾焚烧电站非常重要的组成部分,在旁路系统中安装合适的减温减压装置,需要对环形逐级膨胀式装置和两级多孔节流式装置进行重点计算,根据计算结果分析这两类减温减压装置的优势,再结合减温减压装置的性能和旁路系统的需求确定装置类型。The bypass system is a very important system for the waste incineration power station.To install a suitable temperature reduction and decompression device in the bypass system,it is necessary to carry out key calculations on the annular step-by-step expansion device and the two-stage porous throttling device.According to the calculation results,the advantages of the two kinds of temperature and pressure reducing devices are analyzed.Combined with the performance of temperature reducing and pressure-reducing devices and the requirements of bypass system to determine the type of device.

关 键 词:垃圾焚烧 电站旁路 减温减压装置 

分 类 号:TM62[电气工程—电力系统及自动化]

 