太原双工艺污水处理厂微塑料去除效能研究  被引量:4

Research on the removal efficiency of microplastics in Taiyuan dual-process municipal wastewater treatment plant

在线阅读下载全文

作  者:解立国[1,2] 郝文静 张峰 姚亮[1] 崔建国 XIE Li-guo;HAO Wen-jing;ZHANG Feng;YAO Liang;CUI Jian-guo(College of Environmental Science and Engineering,Taiyuan University of Technology,Taiyuan 030024,China;Taiyuan Urban Drainage Management Center,Taiyuan 030006,China)

机构地区:[1]太原理工大学环境科学与工程学院,山西太原030024 [2]太原市城市排水管理中心,山西太原030006

出  处:《应用化工》2022年第4期1049-1054,1059,共7页Applied Chemical Industry

摘  要:为研究中国城市污水处理厂中微塑料(MPs)的赋存及去除规律,采用体视显微镜结合傅里叶变换显微红外光谱仪对太原某双工艺三级污水处理厂MPs进行检测鉴定。结果表明,进水中MPs的浓度为21.0 n/L,处于中等水平;小尺寸(<1000μm)占比最高(77.38%),主要形状是纤维状(90.95%)。整体上检出的聚合物成分中,主要是纤维素(47.22%)和人造丝(35.00%),其次是聚酯(PET,5.56%)和聚丙烯-聚乙烯共聚物(PP-PE,4.44%)。系统1和系统2对MPs的总体去除率分别为78.73%和75.71%,对MPs的去除起主要作用的是一级处理和二级处理阶段,且沉砂池是一级处理中起主要作用的构筑物。深度处理对MPs有一定的去除效果,系统2中起主要作用的是滤池构筑物。虽然污水处理厂出水MPs的浓度为4.5 n/L和5.1 n/L,但每年仍有6.09×10^(3)亿个MPs通过该污水处理厂排放到淡水环境中。In order to study the occurrence and removal of microplastics(MPs)in municipal wastewater treatment plant in China,a dual-process three-stage wastewater treatment plant in Taiyuan was selected as the research object,and a Stereo microscope combined with Fourier transform infrared microscope spectrometer was used to detect and identify MPs.The results showed that the concentration of MPs in the influent was 21.0 n/L,which was at a medium level;small size(<1000μm)accounted for the highest proportion(77.38%),and the main shape was fibrous(90.95%).The main polymer components detected were cellulose(47.22%)and rayon(35.00%),followed by polyester(PET,5.56%)and polypropylene-polyethylene copolymer(PP-PE,4.44%).The overall removal rate of system 1 and system 2 for MPs were 78.73%and 75.71%,respectively.The primary and secondary treatment stages played a major role in the removal of MPs,and the grit tank was the main structure in the primary treatment.The advanced treatment had a certain effect on the removal of MPs,and the filter was the main role in system 2.Although the concentration of MPs in the effluent from the wastewater treatment plant was 4.5 n/L and 5.1 n/L,there were still 609 billion MPs discharged into the freshwater environment through the wastewater treatment plant every year.

关 键 词:污水处理厂 处理工艺 微塑料 去除率 

分 类 号:TQ32[化学工程—合成树脂塑料工业] X52[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象