检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:侯纪波 倪雪辉 黄起建 王公文 张少飞 Hou Jibo;Ni Xuehui;Huang Qijian;Wang Gongwen;Zhang Shaofei(Gree Electric Appliances,INC of Zhuhai)
机构地区:[1]珠海格力电器股份有限公司
出 处:《制冷与空调》2022年第5期92-97,共6页Refrigeration and Air-Conditioning
摘 要:通过研究不同厚度的铝翅片在不同规格的换热器中的传热效率,结合试验测试以及数值模拟结果,分析铝箔厚度对不同规格换热器的换热性能的影响规律。结果表明:翅片的管间距与列距的比值大,翅片传热效率高;铝箔厚度对传热效率低的翅片影响大;管列距为19.05 mm×12.7 mm的Ф7换热器应选择0.095mm的铝箔,而管列距为22mm×19.05mm的Ф8换热器应选择0.105mm的铝箔。By studying the heat transfer efficiency of aluminum fins with different thicknesses in heat exchangers with different specifications,combined with experimental test results,the influence of aluminum foil thickness on the heat transfer performance of heat exchangers with different specifications is analyzed.The results show that:The ratio of fin tube spacing to column spacing is large,and the fins have high heat transfer efficiency.The thickness of aluminum foil has a large effect on fins with low heat transfer efficiency.ForФ7 heat exchangers with a tube-column spacing of 19.05 mm×12.7 mm,0.095-thick aluminum foil is better choices.ForФ8 heat exchangers with a tube-column spacing of 22 mm×19.05 mm,a 0.105-thick aluminum foil is selected.
关 键 词:铝箔厚度 翅片效率 翅片管式换热器 换热性能 试验测试
分 类 号:TB6[一般工业技术—制冷工程]