大型水电站排水控制系统运行异常分析与研究  被引量:1

Analysis and Treatment of an Abnormal Operation Fault of the Drainage Control System in a Large-scale Hydropower Station

在线阅读下载全文

作  者:黄真懿 张堃 周立成[1] 谭勇[1] HUANG Zhenyi;ZHANG Kun;ZHOU Licheng;Tan Yong(Three Gorges Hydropower Plant, China Yangtze Power Co., Ltd., Yichang 443000, China)

机构地区:[1]中国长江电力股份有限公司三峡水力发电厂,湖北宜昌443000

出  处:《水电与新能源》2022年第6期54-57,63,共5页Hydropower and New Energy

摘  要:通过对某大型水电站排水控制系统运行异常分析与研究,从硬件、软件、功能性试验、元器件运行状态等技术层面查明故障症结,经采用应急措施和技术优化,解决了排水系统因控制回路交流感应电压过高导致系统功能紊乱异常的难题,及时保证了设备的安全运行,避免了水淹厂房的重大风险的发生。From the technical aspects of hardware,software,functional test and operation state of components,an abnormal operation fault of the drainage control system in a large-scale hydropower station is analyzed.Emergency treatment measures and technical optimization are then carried out.The dysfunction problem of the drainage system caused by excessively high AC induced voltage in the control circuit is successfully solved.It ensures the operation safety of the equipment and avoids the occurrence of a serious flooding accident of the powerhouse.

关 键 词:水电站 排水控制系统 感应电压 功能紊乱 分析处理 

分 类 号:TV741[水利工程—水利水电工程]

 