无线超高清腔镜系统在经皮肾镜取石术中的应用  被引量:5

Application of a wireless ultra-high-definition endoscopic system in percutaneous nephrolithotomy

在线阅读下载全文

作  者:侯冰冰[1] 樊松[1] 赵磊[1] 王建忠[1] 杨诚[1] 梁朝朝[1] 郝宗耀[1] Bing-bing Hou;Song Fan;Lei Zhao;Jian-zhongWang;Cheng Yang;Chao-zhao Liang;Zong-yao Hao(Department of Urology(Urology Institute of Anhui Medical University),the First Affiliated Hospital of Anhui Medical University,Hefei,Anhui 230022,China)

机构地区:[1]安徽医科大学第一附属医院泌尿外科(安徽医科大学泌尿外科研究所),安徽合肥230022

出  处:《中国内镜杂志》2022年第6期28-32,共5页China Journal of Endoscopy

基  金:国家自然科学基金面上项目(No:82070724);安徽省自然科学基金面上项目(No:1908085MH246);安徽高校协同创新项目(No:GXXT-2019-014);安徽省转化医学研究院科研基金2020年省转化医学研究重大项目(No:ZHYX2020A003)。

摘  要:目的探讨无线超高清腔镜系统应用于经皮肾镜取石术(PCNL)的有效性、安全性和便利性。方法选取2021年5月-2021年7月安徽医科大学第一附属医院收治的肾结石患者74例,分为有线腔镜组(n=38,使用传统有线腔镜系统行PCNL)和无线腔镜组(n=36,使用无线超高清腔镜系统行PCNL)。患者年龄18~70岁,肾结石最大长径20~40 mm,肾功能正常。比较两组患者手术有效性、安全性和操作便利性的差异。结果两组患者均顺利完成手术,两组患者手术时间、血红蛋白下降值、并发症发生率、术后住院时间和一期结石清除率分别为(44.45±12.04)和(43.78±10.11)min(P=0.797)、(10.05±3.45)和(9.78±4.24)g/L(P=0.760)、47.4%和52.8%(P=0.642)、(5.32±1.25)和(5.19±1.04)d(P=0.652)、89.5%和91.7%(P=0.747),两组患者比较,差异均无统计学意义(P>0.05)。结论无线超高清腔镜系统用于PCNL安全有效。相较传统有线腔镜系统,其没有光源线和摄像头电缆线的限制,操作上更加便利,值得在PCNL中推广应用。Objective To discuss the effectiveness,safety and convenience of the wireless ultra-high-definition endoscopic system in percutaneous nephrolithotomy(PCNL).Methods Selected 74 patients with kidney stone from May to July 2021,they were divided into two groups:linear endoscope group(n=38,PCNL using traditional linear endoscope system)and non-linear endoscope group(n=36,PCNL using wireless UHD endoscope system).The inclusion criteria were 18~70 years old,20~40 mm kidney stones,and normal renal function.Compare the effectiveness and safety of the operation,and evaluate the difference in operation convenience between the two groups.Results All PCNL was successfully completed.The operation time,hemoglobin drop,complication rates,the postoperative hospital stay and the stone clearance rate of the two groups were(44.45±12.04)and(43.78±10.11)min(P=0.797),(10.05±3.45)and(9.78±4.24)g/L(P=0.760),47.4%和52.8%(P=0.642),(5.32±1.25)and(5.19±1.04)d(P=0.652),89.5%and 91.7%(P=0.747),the differences were not statistically significant.Conclusion The wireless ultra-high-definition endoscopic system was safe and effective when used in PCNL.Compared with the traditional endoscopic system,it has no restrictions on the light source line and camera cable line,and more convenient in operation.It is worthy of popularization and application in PCNL.

关 键 词:无线 腔镜系统 经皮肾镜取石术 微创 肾结石 

分 类 号:R692.4[医药卫生—泌尿科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象