检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李亚兰 LI Yalan(Gansu Architectural Design and Research Institute Co.,Ltd.,Lanzhou 730070)
机构地区:[1]甘肃省建筑设计研究院有限公司,甘肃兰州730070
出 处:《中国建材科技》2022年第3期127-128,103,共3页China Building Materials Science & Technology
摘 要:对8度(0.2g)区一栋建于1960年的4层底部框架-抗震墙砌体房屋进行抗震加固设计。原结构未经抗震设计,构造柱及圈梁设置偏少,抗震能力明显不足,且底部框架-抗震墙为薄弱层。经二次鉴定,1~2层楼层综合能力指数均不满足现行规范要求。选择合理的加固方案进行加固设计:底部增加嵌砌于框架之间的填充墙,以增加其侧向刚度;采用双面钢筋网水泥砂浆面层法和高延性混凝土单面加固法进行墙体抗震性能加固。加固后,结构抗震性能满足现行规范的要求。The seismic reinforced design of a 4-story masonry building with frame and seismic wall at the bottom layer,which was built in 1960 in zone 8 degree(0.2g),is carried out.The original structure has not been subject to seismic design,the number of structural columns and ring beams are small,the seismic capacity is obviously insufficient,and the bottom frame is a weak layer.Based on the results of second appraisal,the comprehensive seismic capacity index of the first and second floors does not meet the requirements of current codes.A reasonable reinforcement scheme is selected for reinforced design.The filling wall embedded between the frames is added at the bottom to increase its lateral stiffness,and the steel mesh cement mortar surface layer method and the single HDC layer are used for seismic strengthening.After reinforcement,the seismic performance of the structure meets the requirements of current codes.
关 键 词:底部框架-抗震墙砌体结构 抗震加固 楼层综合能力指数
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3