作 者:杨帆[1] 汪波 徐竑雷 刘昕 Yang Fan;Wang Bo;Xu Honglei;Liu Xin(Beijing Institute of Architectural Design,Beijing;Beijing North Star Convention and Exhibition Investment Limited Company,Beijing)
机构地区:[1]北京市建筑设计研究院有限公司,北京 [2]北京北辰会展投资有限公司,北京
出 处:《暖通空调》2022年第6期99-104,共6页Heating Ventilating & Air Conditioning
摘 要:介绍了冬奥会主媒体中心核心技术区的冷源和空调系统。论述了在冬春季供冷工况下室外计算参数的确定、系统的配置、赛时赛后的转换。对设计工况和实际运行参数进行了对比分析,总结了短期临时运行并需确保万无一失的奥运项目的工程设计原则。This article presents the cold source and air conditioning system in the core technology area of the main media center of the Olympic Winter Games, discusses the determination of outdoor calculation parameters under the winter and spring cooling conditions, the configuration of the system, and the conversion after the game. The design conditions and actual operating parameters are compared and analysed, and the engineering design principles of the Olympic projects that operate temporarily for a short time and need to ensure that there is no mistake are summarized.
关 键 词:冬奥会 主媒体中心 室外设计参数 空调系统 冷却塔供冷 赛时赛后转换
分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]