检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王志刚 祝秀娟 周蕾 张祎琦 林波 Wang Zhigang;Zhu Xiujuan;Zhou Lei;Zhang Yiqi;Lin Bo(China Architecture Design&Research Group,Beijing)
机构地区:[1]中国建筑设计研究院有限公司,北京
出 处:《暖通空调》2022年第6期105-110,共6页Heating Ventilating & Air Conditioning
摘 要:分析了该项目实现近零能耗的设计难点,介绍了为实现近零能耗,建筑和暖通空调系统所应用的节能技术。模拟计算了该项目的全年运行能耗及节能率,结果显示,与基准建筑相比,全年供暖能耗降低51%,空调能耗降低26.4%,建筑本体节能率为35.6%。The design difficulties of realizing near-zero energy consumption in this project are analysed, and the energy-saving technologies applied to the building and the HVAC system to achieve near-zero energy consumption are presented. The annual operating energy consumption and energy-saving rate of the project are simulated and calculated. The results show that compared with the standard building, the annual heating energy consumption is reduced by 51%, the air conditioning energy consumption is reduced by 26.4%, and the building energy-saving rate is 35.6%.