作  者:张维[1] 韩跃华[2] 王玉婷 熊志娟 杜勤[2] 谢勇[3] 陆红[1] Zhang Wei;Han Yuehua;Wang Yuting;Xiong Zhijuan;Du Qin;Xie Yong;Lu Hong(Department of Gastroenterology,Renji Hospital,Shanghai Jiaotong University School of Medicine,Shanghai 200120,China;Department of Gastroenterology,the Second Affiliated Hospital of Zhejiang University School of Medicine,Hangzhou 310003,China;Department of Gastroenterology,the First Affiliated Hospital of Nanchang University,Nanchang 330006,China)

机构地区:[1]上海交通大学医学院附属仁济医院消化科,上海200120 [2]浙江大学医学院附属第二医院消化科,杭州310003 [3]南昌大学第一附属医院消化科,南昌330006

出  处:《中华消化杂志》2022年第3期158-162,共5页Chinese Journal of Digestion

摘  要:目的评价卡式尿素[^(14)C]呼气试验药盒、闪烁采样瓶(固体闪烁法)、液体闪烁式(以下简称液闪式)尿素[^(14)C]呼气试验药盒诊断幽门螺杆菌(H.pylori)感染的效果。方法纳入2020年1月7日至10月28日在上海交通大学医学院附属仁济医院、浙江大学医学院附属第二医院、南昌大学第一附属医院就诊的239例患者。所有受试者均先接受^(14)C尿素呼气试验,气体收集结束后>1~<7 d于胃镜下取黏膜组织行金标准检测,即活体组织检查(以下简称活检)和快速尿素酶检查(RUT),活检与RUT均提示H.pylori阳性则判定金标准检测结果为H.pylori阳性,均提示H.pylori阴性则判定金标准检测结果为H.pylori阴性,活检与RUT结果不一致则不纳入后续分析。以金标准检测结果为参照,分析卡式尿素[^(14)C]呼气试验药盒、闪烁采样瓶、液闪式尿素[^(14)C]呼气试验药盒诊断H.pylori感染的灵敏度、特异度、准确度、阳性预测值、阴性预测值,评价其诊断效果。记录检测过程中有无出现检测相关不良事件以评估试验的安全性。采用描述性方法进行统计学分析。结果239例受试者中,12例未完成试验,最终227例受试者完成检测,试验完成率为95.0%(227/239),其中第008号受试者缺少液闪式呼气检测结果,仅纳入卡式尿素[^(14)C]呼气试验药盒和闪烁采样瓶结果分析。金标准检测结果显示,227例患者中,87例呈H.pylori阳性,118例呈阴性,22例活检与RUT结果不一致故不纳入后续分析;除去008号受试者,金标准检测结果中86例呈H.pylori阳性,118例呈阴性。以金标准检测结果为参照,卡式尿素[^(14)C]呼气试验药盒、闪烁采样瓶、液闪式尿素[^(14)C]呼气试验药盒诊断H.pylori感染的灵敏度、特异度、准确度、阳性预测值、阴性预测值分别为91.9%、100.0%、96.6%、100.0%、94.4%,95.4%、97.5%、96.6%、96.5%、96.6%,96.5%、99.2%、98.0%、98.8%、97.5%。试验过程中仅发生1例�Objective To evaluate the effects of the cassette ^(14)C-urea breath test kit,scintillation sampling bottle(solid-state scintillation method)and liquid scintillation ^(14)C-urea breath test kit in the diagnosis of Helicobacter pylori(H.pylori)infection.Methods From January 7 to October 28,2020,239 patients were enrolled who visited Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine,the Second Affiliated Hospital of Zhejiang University School of Medicine and the First Affiliated Hospital of Nanchang University.All subjects first received ^(14)C-urea breath test.Within>1 to<7 days after gas collection,mucosal tissues were taken under gastroscopy for gold standard test,including biopsy and rapid urease test(RUT).If both biopsy and RUT indicated H.pylori positive,the result of gold standard test was H.pylori positive,and if both were negative,the result of gold standard test was H.pylori negative.If the results of biopsy and RUT were inconsistent,they were not included in the subsequent analysis.Based on the results of gold standard test,the sensitivity,specificity,accuracy,positive predictive value and negative predictive value of the cassette ^(14)C-urea breath test kit,scintillation sampling bottle,and liquid scintillation ^(14)C-urea breath test kit in the diagnosis of H.pylori infection were analyzed.The safety of the test was evaluated by whether there were any adverse events during the test.Descriptive methods were used for statistical analysis.Results Among the 239 subjects,12 cases did not complete the test,227 subjects finally completed the test.The test completion rate was 95.0%(227/239).No.008 patient was only included in the analysis of cassette ^(14)C-urea breath test kit and scintillation sampling bottle because of lacking the result of liquid scintillation breath test.The results of gold standard test showed that among 227 patients,87 cases were H.pylori positive,118 cases were H.pylori negative.The results of biopsy and RUT were inconsistent in 22 cases,so they were not incl

关 键 词:呼气试验 幽门螺杆菌 卡式尿素[^(14)C]呼气试验药盒 闪烁采样瓶(固体闪烁法) 液体闪烁式尿素[^(14)C]呼气试验药盒 

分 类 号:R446.5[医药卫生—诊断学] R573[医药卫生—临床医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象