3D显微镜下椎弓钉固定治疗寰枢椎骨折脱位  被引量:1

3D microscope assisted posterior pedicle screw internal fixation for atlantoaxial fracture and dislocation

在线阅读下载全文

作  者:丰瑞兵 胡昊 吴刚[1] 黄一拯 李超 张海涛 李朝文 黄勇 FENG Rui-bing;HU Hao;WU Gang;HUANG Yi-zheng;LI Chao;ZHANG Hai-tao;LI Chao-wen;HUANG Yong(Department of Spinal Surgery,Hubei Hospital of Traditional Chinese Medicine,Wuhan,430074 China;Graduate School,Wuhan Institute of Sports Education,Wuhan,430070,China)

机构地区:[1]湖北省中医院脊柱外科,湖北武汉430074 [2]武汉体育学院研究生院,湖北武汉430070

出  处:《中国矫形外科杂志》2022年第11期1012-1015,共4页Orthopedic Journal of China

基  金:湖北省卫生健康委员会项目(编号:WJ2021M182);湖北省中医院院内课题(编号:20190619、20191011)。

摘  要:[目的]介绍3D显微镜下椎弓钉固定治疗寰枢椎骨折脱位的手术技术和初步临床效果。[方法] 2018年1月—2020年6月本科采用3D显微镜下椎弓钉固定治疗寰枢椎骨折脱位患者11例。术前经PACS系统测量椎弓钉置钉长度与角度,术中行颈后路显露寰枢椎后方结构,在3D显微镜下对术野精准止血,利用磨钻对寰枢椎进钉点开口,置入椎弓钉并连接两侧钛棒,根据透视情况,适当提拉复位,于寰枢椎后方植入自体骨颗粒。[结果]11例患者均顺利完成手术。共置入椎弓钉44枚,其中0级与Ⅰ级置钉42枚,置钉优良率95.45%。所有患者均获随访,随访时间12~24个月,平均(16.36±4.72)个月,VAS评分由术前的(6.36±1.63)分,显著降低至术后1年的(1.27±1.10)分,差异有统计学意义(P<0.05);JOA评分由术前的(11.91±2.84)分,显著提高至术后1年的(15.55±1.51)分,差异有统计学意义(P<0.05)。[结论] 3D显微镜下椎弓钉固定治疗寰枢椎骨折脱位疗效确切,术中置钉精准,手术安全性高。[Objective] To introduce the surgical technique and preliminary clinical results of 3D microscope assisted pedicle screw fixation for atlantoaxial fracture and dislocation. [Methods] From January 2018 to June 2020, 11 patients received 3D microscope assisted pedicle screw fixation for atlantoaxial fracture and dislocation. The length and angle of pedicular screw placement were measured by PACS system before operation. After posterior atlantoaxial structures were exposed through posterior cervical approach, the operation field was accurately hemostatic under 3D microscope. The entry point of atlantoaxial screw was opened by grinding drill, and the pedicle screw was placed and connected with titanium rods on both sides, which were adjusted to reduce the atlantoaxial alignment under fluoroscopy. Finally,bone autografts in granule were implanted behind the atlantoaxial vertebrae. [Results] All patients had operation completed successfully with 44 pedicle screws placed totally, and 42 screws inserted in 0 and I grades with accuracy of 95.45%. The VAS score decreased significantly from(6.36±1.63) to(1.27±1.10)(P<0.05), whereas the JOA score increased significantly from(11.91±2.84) preoperatively to(15.55±1.51) at 1 year after operation. [Conclusion] This 3D microscopic assisted pedicle screw fixation is an effective treatment for atlantoaxial fracture and dislocation, with improving accuracy of intraoperative screw placement and operation safety.

关 键 词:寰枢椎骨折脱位 3D显微镜 椎弓钉固定 

分 类 号:R683.2[医药卫生—骨科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象