10 k V自动更换式跌落熔断器的设计及仿真分析  

Design and Simulation Analysis of 10 kV Automatic Replacement Type Drop Fuse

在线阅读下载全文

作  者:吴远密 许守东 Wu Yuanmi;Xu Shoudong(Xishuangbanna Power Supply Bureau,Yunnan Power Grid Co.Ltd.,Jinhong 666100,China;Electric Power Research Institute,Yunnan Power Grid Co.Ltd.,Kunming 650217,China)

机构地区:[1]云南电网有限责任公司西双版纳供电局,云南景洪666100 [2]云南电网有限责任公司电力科学研究院,云南昆明650217

出  处:《云南电力技术》2022年第3期73-76,共4页Yunnan Electric Power

摘  要:本文基于现有10 kV跌落熔断器结构,设计了一种具备自动重合闸、远程主动拉合功能的自动更换熔丝的跌落熔断器,并对10 kV自动更换式跌落熔断器的设计结构进行电场、温度环境理论和仿真分析,最终验证了10 kV自动更换式跌落熔断器的设计可行。In this paper,based on the existing 10 kV drop fuse structure,design a kind of have the function of automatic reclosing,remote active automatically change the fuse drop fuse,and 10 kV automatic replacement type drop fuse design structure of the electric field and the temperature environment theory and simulation analysis,the final validation for 10 kV automatically change the design of the falling type fuse is feasible.

关 键 词:跌落熔断器 自动更换式 绝缘特性 