检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:曾敏 王华 邹均名 李文斌 ZENG Min;WANG Hua;ZOU Junming;LI Wenbin(China CEC Engineering Corporation,Changsha,Hu’nan Province,410114)
机构地区:[1]中国轻工业长沙工程有限公司,湖南长沙410114
出 处:《中国造纸》2022年第4期102-106,共5页China Pulp & Paper
摘 要:本文从内表面防结露、夏季隔热2个角度出发,对夏热冬冷及夏热冬暖地区代表城市采用的钢结构屋面的保温(隔热)层厚度进行计算分析。研究表明,在夏季室内温、湿度达到某一状态时,隔热厚度要大于冬季防结露的保温厚度。因此,夏热冬冷地区的造纸车间钢屋面保温层厚度应按夏季隔热计算确定,并进行冬季防结露验算;夏热冬暖地区按照冬季防结露计算即可。From the perspectives of anti-condensation on the inner surface and heat insulation in summer,the thickness of the thermal-preservation(thermal insulating)layer of the steel structure roof was calculated and analyzed,which adopted by the representative cities in the hot-summer and cold-winter zones and the hot-summer and warm-winter regions,respectively.It pointed out that the thickness of thermal insulating would be greater than the thickness of anti-condensation in winter when the indoor temperature and humidity reached a certain state in summer.Therefore,the thickness of the steel roof insulation layer of the papermaking workshop in hot-summer and cold-winter zones should be calculated by its thermal insulating in summer and checked by the anti-condensation in winter;for hot-summer and warm-winter zones,it should be calculated by the anti-condensation in winter.
分 类 号:TS78[轻工技术与工程—制浆造纸工程] TU277.37[建筑科学—建筑设计及理论]