太阳能光伏跟踪系统中驱动方式对结构的影响分析  被引量:3

Influence of Driving Modes on Structure in Solar Photovoltaic Tracking System

在线阅读下载全文

作  者:丁晓勇 肖斌[2] 朱文逸 朱彦飞 陈昌宏[5] DING Xiaoyong;XIAO Bin;ZHU Wenyi;ZHU Yanfei;CHEN Changhong(Shanghai Electrical Engineering Design Co. Ltd., Shanghai 201109,China;PowerChina Northwest Engineering Co. Ltd.,Xi'an 710065,China;Vooyage International Co. Ltd,Shanghai 201611,China;School of Civil Engineering,Xi'an University of Architecture and Technology,Xi'an 710055,China;School of Mechanics, Civil Engineering and Architecture,Northwestern Polytechnical University,Xi'an 710129,China)

机构地区:[1]上海电气工程设计有限公司,上海201199 [2]中国电建集团西北勘测设计研究院有限公司,西安710065 [3]上海维旺光电科技有限公司,上海201611 [4]西安建筑科技大学土木工程学院,西安710055 [5]西北工业大学力学与土木建筑学院,西安710129

出  处:《西北水电》2022年第3期129-134,共6页Northwest Hydropower

摘  要:风荷载是导致平单轴跟踪支架结构扭转失效的主要荷载,国内外通过增加阻尼器或通过多点驱动的方式改善结构风致扭转效应。本文结合工程实际,基于SAP2000有限元软件,计算分析了单点驱动(无阻尼器)、单点驱动(考虑阻尼器)、多点驱动对光伏跟踪支架性能及风致扭转响应的影响,其中阻尼器布置于主梁(主轴)端部与边立柱连接处。结果表明,阻尼器的增设和多点驱动方式均可改善跟踪系统的振动特性,降低风致扭转变形,改善主梁(主轴)的扭矩分布,降低立柱最大弯矩,减小结构水平位移,节省结构材料用量等。Wind load is the main load leading to torsional failure of flat single-axis tracking bracket structure.At home and abroad,the wind-induced torsional effect of the structure is improved by adding dampers or by means of multi-point driving.Combined with engineering practice and based on SAP2000 finite element software,the influences of single point drive(without damper),single point drive(with damper)and multi-point drive on the performance and wind-induced torsional response of photovoltaic tracking bracket are calculated and analyzed.The damper is arranged at the connection between the end of the main beam(main axis)and the side column.The results show that the addition of damper and multi-point drive can improve the vibration characteristics of the tracking system,reduce the wind-induced torsional deformation,improve the torque distribution of the main beam,reduce the maximum bending moment of the column,reduce the horizontal displacement of the structure,and save the structural materials.

关 键 词:跟踪光伏支架 单点驱动 阻尼器 多点驱动 SAP2000 

分 类 号:TM615[电气工程—电力系统及自动化] TU312.3[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象