臭氧催化氧化技术应用于工业园区污水厂深度降解有机物的中试研究  被引量:3

Application of Pilot-scale Catalytic Ozonation to the Advanced Treatment of Organics in the Industrial Park Wastewater Treatment Plant

在线阅读下载全文

作  者:周泽婷 张浩翔 刘飞峰 Zhou Zeting;Zhang Haoxiang;Liu Feifeng(Shanghai Zhongyao Environmental Protection Industry Co.,Ltd.,Shanghai 200092,China)

机构地区:[1]上海中耀环保实业有限公司,上海200092

出  处:《广东化工》2022年第12期143-145,150,共4页Guangdong Chemical Industry

摘  要:针对工业园区污水厂二级生化处理单元出水有机物降解不彻底、出水水质不易达标的现状,采用连续流臭氧催化氧化装置考察了臭氧投加量和接触反应时间对COD去除效果的影响,并对其运行费用进行评估。结果表明,在臭氧投加量为60mg/L、接触反应时间为1.0h的条件下,出水COD浓度可低于30mg/L,满足准IV类水质排放标准对COD指标的要求,实现了二级生化处理单元出水一步达标,其吨水运行成本为1.17元,约为同等条件下Fenton氧化工艺单元运行成本的1/2,技术经济优势明显。The pilot-scale catalytic ozonation device with continuous flow was used to research into the removal rate of COD in the industrial park wastewater treatment plant,in order to ameliorate the situation which organics have still existed in the effluent of secondary bio-treatment and exceeded the standard.It was demonstrated that 60 mg/L dosage of ozone and 1.0 h of HRT could bring about COD less than 30 mg/L when treating the effluent of the secondary sedimentation tank,which could achieve discharging standard of surface water quality,quasi Class IV by one-step.The operational cost was evaluated showing that 1.17 RMB/m3of catalytic ozonation outstripped 2.17 RMB/m3 of Fenton oxidation from the aspect of technical economy.

关 键 词:臭氧催化氧化 难降解有机物 深度处理 工业废水 运行费用 

分 类 号:X703[环境科学与工程—环境工程]

 