溶剂再生塔塔体开裂失效案例分析  

Cracking Failure Case Analysis of Solvent Regenerated Tower Body

在线阅读下载全文

作  者:王步敢 唐华 Wang Bugan;Tang Hua(Guangyuan Special Equipment Supervision and Inspection Institute,Guangyuan ichuan 628017)

机构地区:[1]广元市特种设备监督检验所,四川广元628017

出  处:《西部特种设备》2022年第2期72-75,共4页Western Special Equipment

摘  要:本文介绍了四川某含硫天然气净化装置中溶剂再生塔的主要参数及工艺流程。在定检过程中发现塔体开裂泄漏,分析原因为违规安装管道支架垫板,导致局部应力集中,同时由于管道振动剧烈导致塔体产生贯穿性裂纹。经过维修和支架改进,延长了设备的使用寿命。The main parameters and process flow of solvent regeneration tower in a sulfur gas purification plant in Sichuan are introduced.The cracking and leaking of the tower body were found in the process of inspection,and the main reason was the illegal installation of the pipe support pad,which led to local stress concentration.At the same time,the penetrating crack of the tower body was produced due to the violent vibration of the pipe.After maintenance and support improvement,prolong the service life of the equipment.

关 键 词:溶剂再生塔 贯穿性裂纹 局部应力集中 管道剧烈振动 