检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:戴犀尊 罗学科[2] 姜子豪 蒋凯 DAI Xi-zun;LUO Xue-ke;JIANG Zi-hao;JIANG Kai(The Research Institute of Mechanical and Electrical Engineering,North China University of Technology,Beijing 100144,China;Beijing Institute of Graphic Communication,Beijing 102600,China)
机构地区:[1]北方工业大学机电工程研究所,北京100144 [2]北京印刷学院,北京102600
出 处:《现代化工》2022年第7期251-254,共4页Modern Chemical Industry
基 金:国家自然科学基金项目(51205005);北京市科技创新服务能力建设项目(PXM2017-014212-000013)。
摘 要:以总磷参数为研究对象,研发了一种基于微型光谱技术的水质在线监测仪。采用嵌入式技术,基于紫外光谱检测原理,利用最小二乘法建立了回归模型,绘制了总磷参数的浓度-吸光度标准工作曲线。实验结果表明,在0~50 mg/L量程范围内,其拟合优度≥0.998 4。对配置的不同浓度的总磷标准溶液进行检测,相对标准偏差(RSD)为2.20%~2.65%;直线性为1.08%~3.51%;相对误差为5.67%~7.01%。实验结果与国标法相对比无明显差别。该监测仪具有实时性好、稳定性高等特点,为水质在线监测提供技术支持,尤其适用于站房式、浮标式水质监测。Taking total phosphorus parameters as the research object, an online water quality monitor based on micro-spectral technology is developed.The monitor adopts an embedded technology, based on the principle of ultraviolet spectrum detection.A regression model is established by means of the least square method, and the concentration-absorbance standard working curve for total phosphorus parameters is drawn.Experimental results show that in the range of 0-50 mg·L,the goodness of fit exceeds 0.998 4.The monitor is used to detect the prepared total phosphorus standard solutions with different concentrations, the relative standard deviation(RSD) is 2.20%-2.65%,the linearity is 1.08%-3.51%,the relative error is 5.67%-7.01%,and there is no obvious difference between this method and national standard method.The monitor shows good real-time performance and high stability characteristics.It can provide technical support for on-line water quality monitoring, especially for station-room and buoy water quality monitoring.
分 类 号:TP216[自动化与计算机技术—检测技术与自动化装置]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.33