微动勘探中噪声场分布的不均匀性对圆形和直线形台阵的影响研究  被引量:6

Study on the influence of the inhomogeneity of noise field distribution on circular and linear array in microtremor exploration

在线阅读下载全文

作  者:杜亚楠 龚雪 徐佩芬[2,3,4] 凌甦群 李传金 DU YaNan;GONG Xue;XU PeiFen;LING SuQun;LI ChuanJin(Xiongan Urban Planning and Design Institute Co.,Ltd.,Baoding 071700,China;Key Laboratory of Shale Gas and Geoengineering,Institute of Geology and Geophysics,Chinese Academy of Sciences,Beijing 100029,China;Innovation Academy of Earth Science,CAS,Beijing 100029,China;College of Earth and Planetary Sciences,University of Chinese Academy of Sciences,Beijing 100049,China;Beijing Zhongkejiao Energy and Environment Technology Co.,Ltd.,Beijing 100083,China;Geo-Analysis Institute Co.,Ltd,Tokyo 184-0012,Japan;School of Civil Engineering,Fujian University of Technology,Fuzhou 350118,China;Institute of Geotechnical Engineering,Fujian University of Technology,Fuzhou 350118,China)

机构地区:[1]雄安城市规划设计研究院有限公司,保定071700 [2]中国科学院地质与地球物理研究所,中国科学院页岩气与地质工程重点实验室,北京100029 [3]中国科学院地球科学研究院,北京100029 [4]中国科学院大学地球与行星科学学院,北京100049 [5]北京中科吉奥能源环境科技有限公司,北京100083 [6]日本地学数据分析研究所,东京184-0012 [7]福建工程学院土木工程学院,福州350118 [8]福建工程学院岩土工程所,福州350118

出  处:《地球物理学进展》2022年第3期1007-1012,共6页Progress in Geophysics

基  金:福建省自然科学基金高校联合资助面上项目(2018J01620)资助。

摘  要:为了研究微动勘探中噪声场分布的不均匀性对常用的圆形和直线形台阵提取频散曲线结果的影响,本文通过模拟噪声数据,定量分析了噪声源集中在某一方向或各向均匀分布时,利用直线形和圆形台阵得到实测频散曲线和理论频散曲线的误差.结果表明,圆形台阵的适用性较强,噪声场分布的不均匀性对提取得到的频散曲线影响较小,而直线形台阵的适用性取决于场地条件,当噪声源满足各向均匀分布时,直线形台阵可提取得到可靠的频散曲线,但当场地条件难以满足噪声源各向均匀分布时,提取得到的频散曲线误差较大.因此,即使直线形台阵施工方便,也要慎重使用.In order to study the influence of the inhomogeneity of the noise field distribution on the results of the dispersion curve extracting from the commonly used circular and linear array in microtremor exploration,this paper quantitatively analyzes the errors of measured and theoretical dispersion curves obtained by linear and circular arrays when the noise sources are concentrated in a certain direction or uniformly distributed by simulating noise data.The results show that the applicability of circular array is flexible enough and the non-uniformity of noise field distribution has little influence on the extracted dispersion curve,while the applicability of linear array depends on the site conditions.When the wave field is isotropic,the linear array can obtain reliable dispersion curve,but when the isotropic condition cannot be satisfied,the error of extracting dispersion curve is great.Therefore,even if the linear array is convenient for field construction,it should be used carefully.

关 键 词:微动勘探 直线形台阵 圆形台阵 噪声场分布 

分 类 号:P631[天文地球—地质矿产勘探]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象