移植肝剪切波速度与肝功能的相关性研究  

Correlation Analysis Between Shear Wave Velocity and Liver Function in Transplanted Liver

在线阅读下载全文

作  者:潘宜鹏 武杜杜 高农 陈梅 王立波[2] 任秀昀[3] Pan Yipeng;Wu Dudu;Gao Nong;Chen Mei;Wang Libo;Ren Xiuyun(Department of Transplantation,The Second Affiliated Hospital of Hainan Medical University,Haikou 570100,China;Department of Ultrasound,Hainan Hospital of PLA General Hospital,Sanya,Hainan 572000,China;Department of Ultrasound,The Third Medical Center of PLA General Hospital,Beijing 100039,China)

机构地区:[1]海南医学院第二附属医院移植科,海口市570100 [2]解放军总医院海南医院超声诊断科,海南省三亚市572000 [3]解放军总医院第三医学中心超声诊断科,北京市100039

出  处:《中国超声医学杂志》2022年第7期787-790,共4页Chinese Journal of Ultrasound in Medicine

基  金:北京市自然科学基金(No.7212139)。

摘  要:目的 应用声辐射力脉冲(ARFI)技术检测移植肝组织剪切波速度,探讨移植肝组织硬度与肝功能的关系。方法 回顾性分析146例肝移植术后患者临床资料,肝移植受者均进行了ARFI检查,测量移植肝组织的剪切波值,并进行分组分析。结果 (1)酶学正常组和酶学增高组以及胆红素正常组和增高组的剪切波值分别为(1.23±0.30)m/s和(1.41±0.43)m/s,(1.25±0.32)m/s和(1.48±0.47)m/s,差异均具有统计学意义。(2)各酶学指标及胆红素指标分别与移植肝剪切波值呈正相关,相关系数为0.621、0.404、0.482、0.570和0.573,P<0.05。(3)肝移植术后1年以上和1年以内组的剪切波值分别为(1.24±0.37)m/s和(1.59±0.53)m/s,差异具有统计学意义;肝移植术后≤7 d组的剪切波值为(1.95±0.69)m/s,明显高于其他时间段组的剪切波值。结论 移植肝组织硬度升高与肝脏肝功能异常相关,剪切波速度在评估移植肝功能时具有重要临床价值。Objective Acoustic radiation force impulse(ARFI) technique was used to detect the shear wave velocity of transplanted liver tissue to investigate the relationship between the hardness of transplanted liver tissue and liver function. Methods The clinical data of 146 patients after liver transplantation were retrospectively analyzed. ARFI examination was performed on all liver transplantation recipients, and shear wave value of transplanted liver tissue was measured. Results(1)The shear wave values of normal enzyme group and increased enzyme group were(1.23±0.30) m/s and(1.41±0.43) m/s, respectively;The shear wave values of the normal and elevated bilirubin groups were(1.25±0.32) m/s and(1.48±0.47) m/s, respectively.The differences between the two groups were statistically significant.(2)The enzyme indexes and bilirubin indexes were positively correlated with the shear wave value of transplanted liver, respectively, with the correlation coefficients of 0.621, 0.404, 0.482, 0.570 and 0.573(P<0.05).(3)The shear wave values of more than one year and less than one year after liver transplantation were(1.24±0.37) m/s and(1.59±0.53) m/s, respectively, with statistically significant differences between the two groups. The shear wave value of the ≤7 d group after liver transplantation was(1.95±0.69) m/s, which was significantly higher than that of other time groups. Conclusions Increased hardness of transplanted liver tissue is associated with abnormal liver function, and shear wave velocity has important clinical value in evaluating transplanted liver function.

关 键 词:肝移植 声脉冲辐射力弹性成像 剪切波 

分 类 号:R657.3[医药卫生—外科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象