检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Siwen Gu Lei Zhang Yu Zhuang Weida Li Jian Du Cheng Shao
机构地区:[1]Institute of Chemical Process Systems Engineering,School of Chemical Engineering,Dalian University of Technology,Dalian 116024,China [2]Jiangsu Collaborative Innovation Center for Cultural Creativity,School of Photoelectric Engineering,Changzhou Institute of Technology,Changzhou 213032,China [3]Institute of Advanced Control Technology,School of Control Science and Engineering,Dalian University of Technology,Dalian 116024,China
出 处:《Chinese Journal of Chemical Engineering》2022年第7期231-244,共14页中国化学工程学报(英文版)
基 金:financial support from Jiangsu Collaborative Innovation Center for Cultural Creativity (XYN1911);the National Natural Science Foundation of China (22008023;21776035);Natural Science Foundation of Jiangsu Education Department (20KJB510041)
摘 要:Because of its paramount importance in the successful industrial control strategy of a given heat exchanger network(HEN),the control structure designs for providing appropriate manipulated variable(MV)and controlled variable pairings have received considerable attention.However,quite frequently HENs with such control structures face the problem of hard constraints,typically holding the HENs at less controlled operating space.So both the MV pairings and the above control pairings should be considered to design a control structure.This paper investigates the systematic incorporation of the two pairings,and presents a methodology for designing such two-tier control structure.This is developed based on the sequential strategy,coupling an indirect-tier with direct-tier control structure design,wherein the intention is realized in the former stage and the latter is implemented for further optimization.The MV identification and pairing are achieved through variations in heat load of heat exchangers to design the indirect-tier control structure.Then the direct-tier control structure is followed the relative gain array pairing rules.With the proposed methodology,on the one hand,it generates an explicit connection between the MV pairings and the HEN configuration,and the quantitative interaction measure is improved to avoid the multiple solutions to break the relationship among all the control pairings into individuals;on the other hand,a two-tier control structure reveals control potentials and control system design requirements,this may avoid complex and economically unfavourable control and HEN structures.The application of proposed framework is illustrated with two cases involving the dynamic simulation analysis,the quantitative assessment and the random test.
关 键 词:Heat exchanger networks(HENs) CONTROLLABILITY Two-tier control structure Manipulated variable pairing Control pairing
分 类 号:TK172[动力工程及工程热物理—热能工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.148.200.110