Lower-Limb Motion-Based Ankle-Foot Movement Classification Using 2D-CNN  

在线阅读下载全文

作  者:Narathip Chaobankoh Tallit Jumphoo Monthippa Uthansakul Khomdet Phapatanaburi Bura Sindthupakorn Supakit Rooppakhun Peerapong Uthansakul 

机构地区:[1]School of Telecommunication Engineering,Institute of Engineering,Suranaree University of Technology,Nakhon Ratchasima,30000,Thailand [2]Department of Telecommunications Engineering,Faculty of Engineering and Technology,Rajamangala University of Technology Isan(RMUTI),Nakhon Ratchasima,30000,Thailand [3]Orthopedic Department School of Medicine,Suranaree University of Technology,Nakhon Ratchasima,30000,Thailand [4]School of Mechanical Engineering,Institute of Engineering,Suranaree University of Technology,Nakhon Ratchasima,30000,Thailand

出  处:《Computers, Materials & Continua》2022年第10期1269-1282,共14页计算机、材料和连续体(英文)

基  金:This work was supported by Suranaree University of Technology(SUT),Thailand Science Research and Innovation(TSRI),and National Science Research and Innovation Fund(NSRF)(NRIIS no.42852).

摘  要:Recently,the Muscle-Computer Interface(MCI)has been extensively popular for employing Electromyography(EMG)signals to help the development of various assistive devices.However,few studies have focused on ankle foot movement classification considering EMG signals at limb position.This work proposes a new framework considering two EMG signals at a lower-limb position to classify the ankle movement characteristics based on normal walking cycles.For this purpose,we introduce a human anklefoot movement classification method using a two-dimensional-convolutional neural network(2D-CNN)with low-cost EMG sensors based on lowerlimb motion.The time-domain signals of EMG obtained from two sensors belonging to Dorsiflexion,Neutral-position,and Plantarflexion are firstly converted into time-frequency spectrograms by short-time Fourier transform.Afterward,the spectrograms of the three ankle-foot movement types are used as input to the 2D-CNN such that the EMG foot movement types are finally classified.For the evaluation phase,the proposed method is investigated using the healthy volunteer for 5-fold cross-validation,and the accuracy is used as a standard evaluation.The results demonstrate that our approach provides an average accuracy of 99.34%.This exhibits the usefulness of 2D-CNN with low-cost EMG sensors in terms of ankle-foot movement classification at limb position,which offers feasibility for walking.However,the obtained EMG signal is not directly considered at the ankle position.

关 键 词:ELECTROMYOGRAPHY neural network tibialis anterior muscle gastrocnemius muscle convolution neural network SPECTROGRAM lower limb 

分 类 号:R873[医药卫生—运动医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象