检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张远琴 ZHANG Yuanqin(Panxi Institute of Vanadium and Titanium Inspection and Testing,Panzhihua,Sichuan Province,617000 China)
出 处:《科技创新导报》2022年第8期11-14,共4页Science and Technology Innovation Herald
摘 要:本文采用连续光源火焰原子吸收光谱法,测定镁电解质中氯化钾、氯化钠钠、氯化镁和氯化钙四元组分含量。通过系列实验,探讨了火焰温度及分析谱线选择等仪器测量参数的选择;通过仪器自动优化功能,对火焰测量参数(燃气流量、助燃比、燃烧头高度)进行优化,并以氯化镧为干扰消除剂,消除钾、钠的电离干扰及NH和SiO对钠和镁的分子吸收光谱干扰。通过精密度和加标回收实验表明,各元素测量相对标准偏差小于1%,回收率在93%~103%。The contents of potassium chloride,sodium chloride,magnesium chloride and calcium chloride in magnesium electrolyte are determined by continuous light source flame atomic absorption spectrometry in this paper.The instrument measurement parameters such as flame temperature and analytical spectral line are discussed through a series of experiments,the flame measurement parameters(gas flow,combustion supporting ratio and combustion head height)are optimized through the automatic optimization function of the instrument,and Lanthanum chloride is used as interference eliminator to eliminate the ionization interference of potassium and sodium and the interference of NH and SiO on the molecular absorption spectrum of sodium and magnesium.The precision and recovery experiments show that the relative standard deviation of each element is less than 1%,and the recovery is 93%to 103%.
分 类 号:TQ153.13[化学工程—电化学工业] O657.31[理学—分析化学]