检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:秦梦丹 王国权 袁琨 王坚 张祥 Qin Mengdan;Wang Guoquan;Yuan Kun;Wang Jian;Zhang Xiang(College of Optical and Electronic Technology,China Jiliang University,Hangzhou 310018,Zhejiang,China;School of Optics and Photonics,Beijing Institute of Technology,Beijing 100081,China;Hangzhou CHNSpec Technology Co.,Ltd.,Hangzhou 310034,Zhejiang,China)
机构地区:[1]中国计量大学光学与电子科技学院,浙江杭州310018 [2]北京理工大学光电学院,北京100081 [3]杭州彩谱科技有限公司,浙江杭州310034
出 处:《光学学报》2022年第14期92-101,共10页Acta Optica Sinica
基 金:浙江省重点研发计划项目(2020C03095);浙江省属高校基本科研业务费专项资金资助项目(2020YW22)。
摘 要:设计了一种分光测色仪,使用氙灯作为分光测色仪的测量光源,设计机械结构调整紫外部分的能量在整个氙灯发光强度中的比例。使用荧光物质比例确定的标准色板作为标准物质对仪器和标准仪器进行校准。设计算法对照明光源进行修正,使得照明光源的紫外光谱辐射强度和标准仪器一致,进而降低台间差。此外,设计了实验对方案效果进行验证。未应用所提方案的仪器在CIELAB均匀颜色空间中:测量无荧光材料颜色台间差ΔE_(ab)的最大值为0.88,平均值为0.44;测量有荧光色台间差ΔE_(ab)的最大值为13.69,平均值为3.46。应用所提方案后仪器在CIELAB均匀颜色空间中:测量无荧光色台间差ΔE_(ab)的最大值为0.88,平均值为0.38;测量有荧光色台间差ΔE_(ab)的最大值为3.88,平均值为1.04。实验结果证明,使用所提方案可以较好地提升不同仪器之间对荧光色测量的台间差水平。In this paper,a spectrophotometer is designed.The xenon lamp is used as the measuring light source of the spectrophotometer,and a mechanical structure is designed to adjust the proportion of ultraviolet energy in the luminous intensity of xenon lamp.The standard color plate determined by the proportion of fluorescent substances is used as the standard substance to calibrate the instrument and the standard instrument.The algorithm is designed to modify the instrument light source to make the ultraviolet spectral radiation intensity of the illumination light source is consistent with that of the standard instrument,so as to reduce inter-instrument agreement.In addition,experiments are designed to verify the effect of the scheme.The maximum value and average value of inter-instrument agreementΔE_(ab)of nonfluorescent materials measured by instruments without the proposed scheme are 0.88 and 0.44 in CIELAB uniform color space,and that in the situation with fluorescence color are 13.69 and 3.46.After applying the proposed scheme,the maximum value and average value of inter-instrument agreementΔE_(ab)of non-fluorescent materials measured by instruments are 0.88 and 0.38 in CIELAB uniform color space,and that in the situation with fluorescence color are 3.88 and 1.04.The experimental results show that the proposed scheme can improve the inter-instrument agreement level of fluorescent color measurement between different instruments.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.33