检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:冉伟铃 徐顺生[1,2] 王控瑶 姚富炼 吴伟 RAN Wei-ling;XU Shun-sheng;WANG Kong-yao;YAO Fu-lian;WU Wei(School of Mechanical Engineering,Xiangtan University,Xiangtan 411105,China;School of Energy Science and Engineering,Central South University,Changsha 410083,China)
机构地区:[1]湘潭大学机械工程学院,湖南湘潭411105 [2]中南大学能源科学与工程学院,湖南长沙410083
出 处:《仪表技术与传感器》2022年第7期34-40,共7页Instrument Technique and Sensor
基 金:湘潭市科技计划项目(CG-YB20201006)。
摘 要:针对目前广泛使用的防护热板恒功率加热导热系数测试方法测试速度慢、难以满足高精度测量的不足,研制了一种基于饱和水恒温加热的导热系数测试装置,并用该测试装置及国内某型高精度中高温防护热板法导热系数测定仪对标准参比板的导热系数进行了对比测量,实验结果表明:在测试温度100~300℃范围内,该测试装置测得的导热系数精度1.5%,优于某型高精度中高温防护热板法导热系数测定仪测量精度3%,测试时间缩短60%以上,测试性能得到明显提升,此新型导热系数测试装置具有较好的推广应用前景。In view of the shortcomings of the widely used thermal conductivity constant heat flow guarded hot plate test meth⁃od,which is slow and difficult to meet the high precision measurement,a thermal conductivity test apparatus based on constant temperature heating of saturated water was developed,and used the test apparatus and a high precision high⁃temperature guarded hot plate method thermal conductivity tester on the thermal conductivity of the standard reference plate of adiabatic materials for comparative measurement.The experimental results show that in the test temperature range of 100~300℃,the accuracy of thermal conductivity measured by this test apparatus is 1.5%,which is significantly better than the measurement accuracy of 3%of a certain type of high⁃temperature guarded hot plate method thermal conductivity tester,the measurement time is shortened by more than 60%.The test performance is significantly improved.This new thermal conductivity testing apparatus has a good prospect for promotion and application.
关 键 词:防护热板法 导热系数 饱和水 恒温加热 测试时长
分 类 号:TP216[自动化与计算机技术—检测技术与自动化装置]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:52.15.120.29