某厂3、4号机组凝结水泵变频深度优化节能分析  被引量:3

Energy Saving Analysis of Frequency Conversion Depth Optimization of Condensate Pump of unit 3 and 4 in Our Plant

在线阅读下载全文

作  者:陈伟[1] CHEN Wei

机构地区:[1]广东红海湾发电有限公司

出  处:《节能与环保》2022年第8期51-52,共2页

摘  要:随着电力市场的不断变化,节能降耗是所有发电企业持续发展的重要策略。某厂结合自身情况,深度探索机组节能潜力,利用机组A修窗口对3、4号机组凝结水泵进行变频深度优化,最大限度地降低厂用电量、降低供电煤耗,进一步达到降低发电成本目的。With the continuous change of the power market,energy conservation and consumption reduction is an important strategy for the sustainable development of all power generation enterprises.Based on our own situation,we explored the energy-saving potential of the unit in depth,and used the unit a repair window to optimize the frequency conversion of the condensate pumps of units 3 and 4,so as to minimize the auxiliary power consumption and reduce the coal consumption of power supply,and further achieve the purpose of reducing the cost of power generation.

关 键 词:凝结水泵 变频 节能 深度优化 效益分析 

分 类 号:TM621[电气工程—电力系统及自动化]

 