检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Liu Xiaoying Yue Yong Wang Chongning Huang Jiazan Huang Xianwei Hao Yanhua 刘晓颖;岳勇;王宠宁;黄家赞;黄贤伟;郝艳华(College of Mechanical Engineering and Automation,Huaqiao University,Xiamen,Fujian,361021,China;The First Affiliated Hospital of Xiamen University,Xiamen,Fujian,361003,China)
机构地区:[1]College of Mechanical Engineering and Automation,Huaqiao University,Xiamen,Fujian,361021,China [2]The First Affiliated Hospital of Xiamen University,Xiamen,Fujian,361003,China
出 处:《Journal of Shanghai Jiaotong university(Science)》2022年第2期240-249,共10页上海交通大学学报(英文版)
基 金:the Natural Youth Science Foundation of Fujian Province(No.2017J05006);the National Natural Science Foundation of China(No.51575196);the Subsidized Project for Postgraduates’Innovation Fund in Scientific Research of Huaqiao University(Nos.18014080034 and 19013080038);the Case Base of Graduate Programs for Professional Degree of Huaqiao University(No.18YJG25)。
摘 要:With the development of economy and the progress of medical science and technology,artificial prosthesis replacement has become an important means to improve the dysfunction caused by human bone diseases.However,there are still some loose phenomena caused by stress shielding.To solve the complications of aseptic loosening after calcaneal prosthesis replacement,an optimal design method for the prosthesis was proposed.The prosthesis was designed and optimized according to the real bone shape and the replacement requirements by the combination of computed tomography(CT)technology,computer-aided design,finite element analysis,and power flow theory.CT data were imported into MIMICS and Geomagic Studios.UG was used to obtain the geometric model of the human skeleton.Then,the 3D finite element model of the prosthesis was established by combining the finite element software Abaqus,and a series of finite element analysis was carried out.The prosthesis was topologically optimized and filled with a porous structure.The prosthesis was implanted by computer simulation.Finally,the power flow method was used to compare the dynamic performance and energy transfer before and after the prosthesis replacement to verify the rationality of the prosthesis design.In this paper,this method was used to optimize the design of the calcaneal prosthesis,and the research shows that this method can reduce the stress shielding effect of the calcaneal prosthesis.From the case of calcaneal prosthesis optimization,this method is not only a supplement to the contemporary biomechanical theory but also can guide the design of bone prosthesis in bone prosthesis replacement surgery.
关 键 词:calcaneal prosthesis finite element optimization design REPLACEMENT
分 类 号:TP391[自动化与计算机技术—计算机应用技术] R319[自动化与计算机技术—计算机科学与技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7