Monte Carlo simulation for performance evaluation of detector model with a monolithic LaBr_(3)(Ce)crystal and SiPM array forγradiation imaging  被引量:3

在线阅读下载全文

作  者:Wei Lu Lei Wang Yong Yuan Ting Zhang Ge Tang Ming-Zhe Liu Xian-Guo Tuo Jing Ning 

机构地区:[1]Chengdu University of Technology,Chengdu 610059,China [2]Sichuan University of Science and Engineering,Zigong 643000,China [3]Beijing Institute of Radiation Medicine,Beijing 100850,China

出  处:《Nuclear Science and Techniques》2022年第8期163-174,共12页核技术(英文)

基  金:supported by the National Natural Science Foundation of China (Nos. 41874121 and U19A2086);the major scientific instruments and equipment development project of the Ministry of Science and Technology,People’s Republic of China (No.2012YQ180118);the Sichuan Science and Technology Program (No.2018JY0181);Sichuan Science and Technology Miao-zi Project(Nos. 2021JDRC0107 and 2021JDRCO068)

摘  要:In recent years,LaBr_(3)(Ce)crystals and silicon photomultipliers(SiPMs)have been increasingly used in radiation imaging.This study involved the establishment of a detector model with a monolithic LaBr_(3)(Ce)crystal and SiPM array forγ-radiation imaging on the GEANT4 platform.The optical process included in the detector model was defined by key parameters,such as the emission spectrum,scintillation yield,and intrinsic resolution of the LaBr_(3):5%Ce crystal,as well as the detection efficiency of the SiPM array.The response of the detector model to^(57)Co flooded field irradiation was simulated and evaluated.The radiation images generated by the detector model exhibited a compression effect that was very close to that on images acquired by the physical detector.The spatial resolution of the simulated detector closely approximates that of the physical experiment.A detector model without the optical process was also established for comparison with a detector using the optical process.Both were used in a near-field modified uniform redundant array(MURA)imaging system to acquire images of a point source and a ring source of^(57)Co at the center of the field-of-view of the imaging system.The spatial resolution and signal-to-noise ratio of the images that were reconstructed using the two detector models were determined and compared.Compared with the detector model without optical processes,although the images from the proposed detector model have slightly inferior signal-to-noise ratios and more artifacts,they are more consistent with the reconstructed versions of images acquired in real physical experiments.The results confirm that the detector model can be used to design aγ-radiation imaging detector and to develop an imaging algorithm that can significantly shorten the development time and reduce the cost.

关 键 词:Scintillation photons Monte Carlo SiPM array Spatial resolution Monolithic LaBr_(3)(Ce)crystal 

分 类 号:TL812[核科学技术—核技术及应用]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象