作 者:陶朝友 刘喜川[1] 林伟[1] 杨洪[1] 代飞[1] 王凯[1] TAO Chaoyou;LIU Xichuan;LIN Wei;YANG Hong;DAI Fei;WANG Kai(Laser Fusion Research Center,China Academy of Engineering Physics,Mianyang 621900,China)
机构地区:[1]中国工程物理研究院激光聚变研究中心,四川绵阳621900
出 处:《原子能科学技术》2022年第8期1707-1713,共7页Atomic Energy Science and Technology
基 金:国家自然科学基金(11804318)。
摘 要:通过建立三维柱腔冷冻靶计算模型,研究了外界环境辐射对间接驱动冷冻靶靶丸及燃料冰层温度场的影响。考虑柱腔内部激光入射孔(LEH)膜透光率对柱腔内靶丸和冰层温度场分布的影响,利用COMSOL软件对柱腔冷冻靶温度场进行了数值模拟计算。研究结果表明:受外界辐射影响,靶丸表面温度场呈两极热、赤道冷分布;LEH膜透光率越大,靶丸外表面温差和冰层内表面温差越大。当LEH膜透光率小于1%时,冰层内表面最大温差低于0.1 mK,可满足冰层均化和保持的要求。实验中,通过在LEH膜上镀不同厚度的铝层调控其透光率,并选择LEH膜镀铝层厚度为35 nm的冷冻靶开展了氘氘冷冻均化实验。结果表明:当LEH膜上的镀铝层厚度为35 nm时,冰层的保持能力得到大幅提升。从X射线相衬图像可知,冰层的厚度均匀性约为80.2%,粗糙度约为1.65μm,平均厚度约为50.5μm。In this work,in order to further optimize the external environment radiation shielding technology of the cryogenic target,through the combination of numerical simulation and experiment,the effect of external environmental radiation on the temperature field distribution of the target and ice layer was studied.Considering the influence of the transmittance of the laser entrance hole(LEH)film on the temperature field distribution of the target and ice layer in the column cavity,the temperature field of a target type in the column cavity was simulated and calculated using COMSOL software.The research results show that the temperature field distribution on the surface of the target is bipolar hot and equatorially cold under the influence of external radiation.Within a certain range,the greater the transmittance of the LEH film,the greater the temperature difference between the outer surface of the target and the inner surface of the ice.When the cylindrical cavity is irradiated with 300 K and the LEH film is pure PI film,the maximum temperature difference on the outer surface of the target pellet is about 20 mK.When the transmittance of the LEH film is less than 1%,the maximum temperature difference of the inner surface of the ice layer is less than 0.1 mK,which can meet the requirements of the ice layering and maintenance.In the experiment,by plating aluminum layers with different thicknesses on the LEH films,the transmittance of the LEH film was adjusted.When the cylindrical cavity was irradiated with 300 K and the LEH film is pure PI film,the deuterium vapor pressure at high temperature is higher than that at low temperature.Therefore,the high pressure deuterium vapor migrates to the low pressure deuterium vapor area,which is finally reflected in the macroscopic view that,within 300 s,the temperature difference drives the ice layer to migrate from two poles to the equator.When the thickness of the aluminum layer on the LEH film was 35 nm,the deuterium layering experiment was carried out.The experimental results sho
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.249