检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:彭有德 岳晨[1] 于文博 葛浩 姚尚军 Youde PENG;Chen YUE;Wenbo YU;Hao GE;Shangjun YAO(College of Energy and Power,Nanjing University of Aeronautics and Astronautics,Nanjing,Jiangsu 210016,China)
机构地区:[1]南京航空航天大学能源与动力学院,江苏南京210016
出 处:《过程工程学报》2022年第8期1124-1136,共13页The Chinese Journal of Process Engineering
基 金:南京航空航天大学研究生科研与实践创新计划资助项目(编号:xcxjh20210206,xcxjh20210210);南京航空航天大学研究生创新基地(实验室)开放基金立项资助项目(编号:kfjj20200204)。
摘 要:为了可以对电镀废水中的金属盐类和水实现高效的资源化回收,且相较于常规蒸发法处理废水更加节能,提出了闭式热泵膜蒸馏电镀废水系统。该系统将膜蒸馏技术与闭式热泵进行耦合,基于质量和能量守恒原理编写膜蒸馏自定义模型,在与实验数据进行对比验证后,通过Aspen Plus仿真平台建立流程来模拟工作情况。通过改变关键操作参数,得到以下结果:进料速度会引起系统功耗的大幅度增加而对于膜蒸馏的潜热的影响较小,因此进料速度对于系统造水比(GOR)影响最大。蒸发温度对于系统的能效比(COP)有着较大的影响,且COP随着蒸发温度的提升而上升,在不同蒸发温度下,系统GOR的下降趋势随进料温度升高先缓再陡。进料浓度对于系统产量比(YRO)有着重要作用,YRO随进料浓度上升而上升;当处在较低的蒸发温度下,不同浓度下的GOR在低进料温度时值较为接近。Electroplating wastewater is one of the extremely harmful sewages, which must be pretreated before being discharged. The evaporation method can be used to pretreat the electroplating waste water and recover it waste resources, but its shortcomings of high energy consumption limit its use. Through coupling a closed heat pump cycle and the membrane distillation process, a novel electroplating wastewater treatment system is proposed in this work to pretreat the electroplating wastewater, the metal salts is recovered and the energy consumption is low. Based on the Aspen Plus simulation platform, the proposed system model is built. After verifying the key components model with the experimental data, the key operating parameters influences on the overall thermodynamic performance of the system have been investigated, and the following results are obtained. Increasing the feed rate caused a substantial increase in the power consumption of the system, but impacted little on the latent heat of the distillation membrane, so the feed rate had the greatest impact on the gain water ratio(GOR) of the system. Due to the increase in processing flow, the yield ratio(YRO) of the system increased slightly, but the feed rate showed almost no effect on the coefficient of performance(COP) of the system.The evaporation temperature had a great influence on the COP of the system, and the COP increased with the increase of the evaporation temperature. The downward trend of the system GOR decreased slowly and then steeply with the feed temperature increase. The GOR of the system was affected by the evaporation temperature and increased as the evaporation temperature was increased. YRO was affected by the combination of evaporation temperature and system power consumption, and showed different trends at high and low feed temperatures. The feed concentration played an important role in the YRO. YRO increased as the feed concentration was increased. The GOR at different concentrations was closer at the low feed temperature. Therefore, these r
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.145