深度学习重建算法在低管电压冠状动脉CT血管成像中的应用  被引量:4

The application of deep learning algorithm reconstruction in low tube voltage coronary CT angiography

在线阅读下载全文

作  者:范婧 杨文洁[1] 王梦真 陆伟 石骁萌 朱宏[1] FAN Jing;YANG Wenjie;WANG Mengzhen;LU Wei;SHI Xiaomeng;ZHU Hong(Department of Radiology,Ruijin Hospital,Shanghai Jiao Tong University School of Medicine,Shanghai 200025,China;GE CT Imaging Research Center,Shanghai 201203,China)

机构地区:[1]上海交通大学医学院附属瑞金医院放射科,上海200025 [2]GE(中国)CT影像研究中心,上海201203

出  处:《诊断学理论与实践》2022年第3期374-379,共6页Journal of Diagnostics Concepts & Practice

摘  要:目的:比较深度学习重建算法(deep learning-based image reconstruction,DLIR)、自适应统计迭代重建算法(adaptive statistical iterative reconstruction-veo,ASiR-V)和滤波反投影重建算法(filtered back-projection,FBP)对低管电压冠状动脉CT血管成像(coronary computed tomographic angiography,CCTA)图像质量的优化效果。方法:前瞻性纳入100例行CCTA扫描的患者,根据其身体质量指数(body mass index,BMI),选择使用70 kVp(50例,BMI≤26 kg/m~2)或80 kVp(50例,BMI>26 kg/m~2)管电压扫描,每例患者的图像分别用FBP(A组)、ASiR-V 50%(B组)、中级DLIR(DLIR-Medium,DLIR-M,C组)和高级DLIR(DLIR-High,DLIR-H,D组)进行重建,比较4组重建算法图像的CT值、噪声、信噪比(signal-to-noise ratio,SNR)和对比噪声比(contrast-noise ratio,CNR),并采用李克特5级评分法对图像质量进行主观评价。结果:在客观图像质量评价中,A、B、C、D 4组两两组间比较,图像噪声、SNR、CNR差异均有统计学意义(P<0.05),其中D组的图像噪声最低,而SNR和CNR最高;在主观图像质量评价中,C组与D组间差异无统计学意义,但均明显高于A组及B组(P<0.05)。结论:在低管电压CCTA扫描中,使用DLIR重建的图像质量优于ASiR-V 50%和FBP,提示DLIR适用于临床低管电压CCTA扫描。Objective:To compare the quality of low tube voltage coronary CT angiography(CCTA) images reconstructed with deep learning-based image reconstruction(DLIR) and with filter back projection(FBP) and with adaptive statistical iterative reconstruction-veo(ASiR-V).Methods:One hundred patients who underwent CCTA were included.The CCTA tube voltage were set as 70 kVp(n=50,BMI≤26 kg/m~2) and 80 kVp(n=50,BMI>26 kg/m~2) according to body mass index(BMI).The images were reconstructed with FBP(Group A),ASIR-V 50%(Group B),DLIR at medium(DLIR-M,Group C) and high DLIR(DLIR-H,Group D) levels,respectively.Objective evaluation indice including CT attenuation,noise,signal-to-noise ratio(SNR),and contrast-to-noise ratio(CNR) were measured or calculated between groups,and Likert5-point scale was adopted for subjective image quality assessment.Results:There were significant differences in image noise,SNR,CNR among the 4 groups(P<0.05),and Group D had the highest SNR and CNR,and lowest noise.There was no significant difference between Group C and Group D in subjective scores,but Group C and D both had higher subjec-tive scores than those of Group A and B(P<0.05).Conclusions:For low tube voltage CCTA,images reconstructed with DLIR generate higher quality,and DLIR may be suitable to apply in low tube voltage CCTA.

关 键 词:冠状动脉CT血管成像 深度学习 迭代重建 辐射剂量 图像质量 

分 类 号:R445.4[医药卫生—影像医学与核医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象