检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:郭坤 GUO Kun(Central-South Architectural Design Institute Co.Ltd.,Wuhan 430064,China)
机构地区:[1]中南建筑设计院股份有限公司,武汉430064
出 处:《工程建设与设计》2022年第17期67-70,共4页Construction & Design for Engineering
摘 要:结合实际工程案例,利用计算流体力学专业软件Fluent 15.0对设置在凹槽内的某超高层公寓变制冷剂流量空调室外机进行气流组织数值模拟,优化室外机的设置位置,设计出合适的室外机布置方案。通过对比实测结果与数值模拟结果,总结方案设计要点。Combined with actual engineering cases,using the professional computational fluid dynamics software Fluent 15.0 to simulate the airflow organization of the outdoor unit of a refrigerant flow air conditioner in a super high-rise apartment set in the groove,to optimize the setting position of the outdoor unit,and design a suitable outdoor unit layout scheme.The main points of the scheme design are summarized by comparing the measured results with the numerical simulation results.
关 键 词:超高层公寓 空调室外机 变制冷剂流量 环境数值模拟 热环境
分 类 号:TU831.4[建筑科学—供热、供燃气、通风及空调工程]