蜡油加氢装置新氢压缩机级间冷却器泄漏分析与预防  被引量:1

Leakage Analysis and Prevention of Interstage Cooler of Makeup Hydrogen Compressor in Wax Oil Hydrogenation unit

在线阅读下载全文

作  者:陆超[1] Lu Chao(CNPC Sichuan Petrochemical Co.,Ltd.,Chengdu Sichuan 611930)

机构地区:[1]中国石油四川石化有限责任公司,四川成都611930

出  处:《山西化工》2022年第6期115-116,145,共3页Shanxi Chemical Industry

摘  要:蜡油加氢装置新压缩机级间冷却器多次发生泄漏,对废旧管束采用宏观检修、材质分析、组织检验等方法,查找冷却器腐蚀泄漏的原因,并采取相应防腐措施,保障设备安全生产和装置长周期平稳运行。The interstage cooler of the new compressor in the wax oil hydrogenation unit has been leaking for many times.The macro maintenance,material analysis,organization inspection and other methods are used to find out the causes of corrosion leakage of the cooler,and corresponding anti-corrosion measures are taken to ensure the safe production of the equipment and the long-term stable operation of the unit.

关 键 词:冷却器 结垢 腐蚀 加氢装置 

分 类 号:TQ050.96[化学工程]

 