检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张帆[1] 范莹莹 刘俊杰[1] 薛人玮 孟晗 Zhang Fan;Fan Yingying;Liu Junjie;Xue Renwei;Meng Han(Tianjin University,Tianjin;Taipei University of Technology,Taipei)
机构地区:[1]天津大学,天津 [2]台北科技大学,中国台湾台北
出 处:《暖通空调》2022年第10期168-173,共6页Heating Ventilating & Air Conditioning
摘 要:由于计算方法的不完善和人员发尘量的不确定,设计人员为了安全,往往采用过大的换气次数,造成了洁净室能源浪费。为了解决这一问题,本研究从洁净度保障原理出发,系统地介绍了洁净室换气次数的计算方法,通过国内外文献调研及分析,探究了人员作为颗粒物发尘主体的特点,得到了人员发尘的粒径特征及发尘量与人员数的非线性规律,对比分析了目前洁净室内的人员发尘当量,总结了洁净室内人员发尘的主要影响因素。发现随着洁净度的降低、洁净服材料的过滤效果变差、洁净服洗涤次数增多、活动强度增大,人员发尘量会增加。研究成果可供洁净室换气次数精准设计参考。Due to the imperfection of the calculation method and the uncertainty of the amount of dust generated by personnel,designers often use excessive air change rates for safety,resulting in a waste of energy in the cleanroom.In order to solve this problem,this study systematically presents the calculation method of air change rate in cleanrooms based on the principle of cleanliness guarantee.Through the investigation and analysis of domestic and foreign literature,it explores the characteristics of personnel as the main body of particulate dust,obtains the particle size characteristics of personnel dust and the nonlinear law between the amount of dust and the number of personnel,compares and analyses the current dust equivalent of personnel in cleanrooms,and summarizes the main influencing factors of personnel dust in cleanrooms.It is found that with the decrease of cleanliness,the poor filtering effect of clean clothes materials,the increase of washing times and activity intensity of clean clothes,the amount of dust generated by personnel will increase.The research results can be used as a reference for the accurate design of air change rate in cleanrooms.
分 类 号:TU834.854[建筑科学—供热、供燃气、通风及空调工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.50