Computational fluid dynamics analysis and experimental hemolytic performance of three clinical centrifugal blood pumps: Revolution, Rotaflow and CentriMag  

在线阅读下载全文

作  者:Dong Han Joshua L.Leibowitz Lu Han Shigang Wang Ge He Bartley P.Griffith Zhongjun J.Wu 

机构地区:[1]Department of Surgery,University of Maryland School of Medicine,Baltimore,MD,USA [2]Fischell Department of Bioengineering,A.James Clark School of Engineering,University of Maryland,College Park,MD,USA [3]Department of Cardiothoracic Surgery,Shanghai Children's Medical Center,Shanghai Jiao Tong University,Shanghai,China [4]Shanghai Key Laboratory of Mechanics in Energy Engineering,School of Mechanics and Engineering Science,Shanghai University,Shanghai,China.

出  处:《Medicine in Novel Technology and Devices》2022年第3期107-114,共8页医学中新技术与新装备(英文)

基  金:The author(s)disclosed receipt of the following financial support for the research,authorship,and/or publication of this article:This work was funded by National Institutes of Health(Grant Numbers:R01HL118372,R01HL124170,R01HL131750,and R01HL141817);This publication was made possible by the University of Maryland Baltimore Institute for Clinical and Translational Research(ICTR)which is funded in part by Grant Number TL1 TR003100 from the National Center for Advancing Translational Sciences(NCATS)a component of the National Institutes of Health(NIH),and NIH Roadmap for Medical Research.Its contents are solely the responsibility of the authors and do not necessarily represent the official view of the University of Maryland Baltimore ICTR,NCATS or NIH.

摘  要:Centrifugal blood pumps have become popular for adult extracorporeal membrane oxygenation(ECMO)due to their superior blood handling and reduced thrombosis risk featured by their secondary flow paths that avoid stagnant areas.However,the high rotational speed within a centrifugal blood pump can introduce high shear stress,causing a significant shear-induced hemolysis rate.The Revolution pump,the Rotaflow pump,and the CentriMag pump are three of the leading centrifugal blood pumps on the market.Although many experimental and computational studies have focused on evaluating the hydraulic and hemolytic performances of the Rotaflow and CentriMag pumps,there are few on the Revolution pump.Furthermore,a thorough direct comparison of these three pumps'flow characteristics and hemolysis is not available.In this study,we conducted a computational and experimental analysis to compare the hemolytic performances of the Revolution,Rotaflow,and CentriMag pumps operating under a clinically relevant condition,i.e.,the blood flow rate of 5 L/min and pump pressure head of 350 mmHg,for adult ECMO support.In silico simulations were used to characterize the shear stress distributions and predict the hemolysis index,while in vitro blood loop studies experimentally determined hemolysis performance.Comparative simulation results and experimental data demonstrated that the CentriMag pump caused the lowest hemolysis while the Revolution pump generated the highest hemolysis.

关 键 词:CFD ECMO support Centrifugal blood pumps HEMOLYSIS 