电动单梁起重机接触器粘连事故分析及控制电路优化改进  被引量:3

Analysis of Contactor Adhesion Accident of Electric Single Beam Crane and Optimization and Improvement of Control Circuit

在线阅读下载全文

作  者:张剑敏 王秀民 白海青 刘庆福 王冬彬 Zhang Jianmin;Wang Xiumin;Bai Haiqing;Liu Qingfu;Wang Dongbin(Dongying Institute of Special Equipment Inspection,Dongying 257000)

机构地区:[1]东营市特种设备检验研究院,东营257000

出  处:《中国特种设备安全》2022年第9期82-84,87,共4页China Special Equipment Safety

摘  要:通过电动单梁起重机接触器触点粘连事故分析,对起重机控制电路进行优化改进,在控制电路中添加时间继电器。在时间继电器线圈回路中,通过上、下行按钮的常闭触点以及上、下行方向接触器的常开触点在运行中触点开闭的转换逻辑,监测相应接触器触点粘连与否,并通过时间继电器延时断开常闭触点与失压脱扣控制断路器配合应用,达到接触器触点粘连的有效防护。Through the analysis of contactor contact adhesion accident of electric single-girder crane,the control circuit of the crane is optimized and improved,time relay is added to the control circuit.In the time relay coil circuit,contact adhesion of the corresponding contactors is monitored through the switching logic of the normally closed contacts of the up and down buttons and the normally open contacts of the up and down direction contactors in the running process.The effective protection of contactor contact adhesion can be achieved through the application of time relay delay disconnecting normally closed contact and voltage loss tripping control circuit breaker.

关 键 词:接触器粘连 控制电路 优化改进 

分 类 号:X943[环境科学与工程—安全科学]

 